Installation Guide

(OPTIONAL) PERMANENT MOUNT
An optional mounting arrangement is to use the two (2) internal bolt holes
with the stiffening plate.
For this option, place the winch Freespool in Disengaged, and spool off enough rope from the winch
drum to insert the steel stiffening plate underneath the winch drum, if it was not Inserted during winch
assembly. To resist the winching loads a minimum of 1/4” (6mm) mounting plate thickness should be
used. Be certain that the structure used for mounting will resist the winching loads of the
WINCH2GO™. Once mounting and wiring is complete, the winch rope may be powered back onto
the drum. See Figure 11a. and 11b.
WHEN USING THE 2 BOLT MOUNTING OPTION, DO NOT USE THE FRONT
SHACKLE HOLE TO DOUBLE-LINE THE PULL BACK TO THE WINCH BASEPLATE. IF
DOUBLE-LINING WITH THE PULLEY BLOCK, ALWAYS SECURE THE WINCH HOOK TO A
NEARBY STRUCTURE, AND NOT THE WINCH BASEPLATE.
7
WINCH2GO™
2-Hole Mounting
Pattern dimensions
Figure 11a.
7
Figure 11b.
Using the supplied M10
mounting bolts, washers,
and nuts, tighten the
mounting hardware
to 32 ft-lb (43 N-m).