Owner's Manual

The folowing funtions are built into the system :
1. Standby mode:
When hooked up to the supply voltage, the system is in standby mode
2. Operational mode:
When the system is in operational mode, the green LED on the receiver will
glow and the system is now ready for use.
3. Automatic stop with frequency interference:
The system will automatically move to standby mode when another
transmitter with the same frequency is detected.
Battery
To change the battery, open the back of the transmitter by removing the two
(2) small screws. After removing the cover, carefully remove the old battery and
replace it with a new CR2450 3 volt coin cell battery. Before installing the new
battery insure that the connector is free from corrosion. Corrosion can
be easily removed using a small sti brush. After the new battery has been
installed, replace the cover carefully by means of the two small screws.
After changing the battery make sure the rubber
seal on the transmitter is in place correctly or the sealing of the unit cannot
be guaranteed. Used batteries should be disposed of according to national
regulations.
CAUTION
!
The transmitter and receiver utilize an internal antenna. This antenna cannot be
shortened, moved or otherwise altered. Alteration will void warranty and may
cause erratic operation.
For safety reasons the receiver also moves to standby mode when more than 5
minutes has elapsed between signals from transmitter to receiver.
The green LED is on when the receiver is on and functional. The red LED ashes
when a button on the transmitter is being pressed.
The receiver works with 3 relays, 2 for direction and 1 for on/o. The relays
switch the current to the proper switch output