Power supply connection
NOTE
Listed Class 2 power unit shall be recommended to use.
The unit is powered by external Listed Class 2 power supply with 12VDC or by Listed to UL 294B PoE power source.
For ULC S319 compliance, connect PSC-100A power supply and Casil CA 1270 battery.
Use a power supply adaptor of DC 12 V (± 10%) with a minimum of 1,500 mA which has obtained the approval of IEC/EN 60950-1. If
you wish to connect and use another device to the power supply adaptor, you should use an adaptor with a current capacity which
is the same or larger than the total power consumption required for the terminal and another device.
Use a separate power supply for Secure I/O 2, the electric lock, and the BioEntry W2 respectively. If connecting and using the power
supply to these devices together, the devices may malfunction.
DO NOT connect the device to the DC power supply(or adapter) and PoE power supply at the same time.
The alarm signal is sent out through AC OK and Battery Low pins in the relay contact type.
Function Description Relay Status
AC OK
AC power is on
Short
AC power is off
Open
Battery Low
The voltage of battery is under 11 V
Short
The voltage of battery is above 11 V
Open
An external voltage source is required for the alarm signal function. The maximum applied voltage is 30 V and the maximum sink
current is 1 A.
Statement indicating that “The PoE Power Source needs to comply with National Electrical Code, ANSI/NFPA 70, Article 725.
121, Power Sources for Class 2 and Class 3 Circuits”.
Category 5e cabling is the minimum performance category recommended. The performance category utilized should match
the transmission speed required at the installation site.
The minimum conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13
mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
When the product is powered via PoE, it must be either UL 294B or UL 294 7th Ed. compliant source.
Compliance with IEEE 802.3 (at or af) specifications shall not be verified as part of these requirements.
BioEntry W2
11 - PWR +VDC Red
13 - PWR GND
Black (White stripe)
Battery Low Alarm
AC OK Alarm