Installation Guide

Installation
18
Wiegand connection
Resetting Network Settings
1 Turn the power on.
2 Press the network reset button on the rear of device until the device restart automatically.
3 Connect the device with default values.
TCP/IP address: DHCP address assignment (If DHCP address assignment is failed, 169.254.x.x will be set.)
Server mode: Disabled
RS-485: Default, 115200 bps
4 Change the TCP/IP address or RS-485 information.
5 Turn the power off later on and then check the network setting is properly.
Restoring the Factory Defaults
This will delete all data and root certificate on the device and reset the settings.
1 Turn the power on.
2 Press the reset button three times quickly.
3 When the green LED is blinking, press the reset button again.
NOTE
If there is no root certificate on the device, you cannot restore the factory defaults.
BioEntry W2
RFID reader
6 - WG D0 Green
7 - WG D1 White
8 - WG GND Black
8
7
6
8
7
6
Use as a Wiegand input device
Use as a Wiegand output device
Control device
BioEntry W2