User's Manual

BioAdmin User Manual 100
Copyright © 2006, 2007 by Suprema Inc. http://www.supremainc.com
z On successful verification, the Wiegand string is also sent to the controller,
which can be checked by operation of relay on the controller.
2.4. Quick start with BioEntry Pass
This section describes the basic procedures to operate BioEntry Pass without a
PC device.
2.4.1. Step 1: Hardware installation
In this configuration, the device is connected to an external controller via Wiegand
interface as well as to the host PC through RS485 interface. It is assumed that the
controller supports the standard 26 bit Wiegand format as default of BioEntry
device.
Host PC
Data 1
Access Controller
Data 0
GND
Network
To other controllers
or host computer
TRX+TRX-
WO_D0
WO_D1
WO_GND
TX+
RX+
RX-
TX-
EARTH
BioEntry Pass
POW_GND
POW+
9~24Vdc
Wiegand I/F
RS485
For more details on the installation, refer to the BioEntry Installation manual or
BEACon Operation Manual.
2.4.2. Step 2: Search new device
z Run BioAdmin software.
z Enter Login ID and password. By factory default, the initial Login ID is “admin
and the password is blank
z Select Device Management on the Main menu, then device management
page will appear on the main window.