User's Manual

BioAdmin User Manual 128
Copyright © 2006, 2007 by Suprema Inc. http://www.supremainc.com
z Press the Write button to initiate issuing.
z The site key management window will appear at the first trial of issuing after
starting of BioAdmin software. Also, the window will appear if it fails to access
the smart card due to the mismatch of the site key.
z Type the current site key to access the smart card. If it remains blank, BioAdmin
software uses default key ( 0xFFFFFFFFFFFF ) as a current site key.
z If it is desired to change the site key on issuing, enable the Change Site Key
check box and type new site key. Then, new site key is updated on the smart
card. The new site key should be correspondent with the site key on BioEntry
Smart device.
3.5.6. Issue with BioEntry Smart
z Place the target smart card at selected BioEntry Smart
z Press the Write button to initiate issuing. Since the site key management
information is stored on BioEntry, issuing is processed without requesting site
key.
3.5.7. User security level and all-time pass card (Bypass) setting
On issuing, security level can be specified for each user. By changing Security
Level dropdown list, user’s security level can be specified from 1/1,000 to
1/100,000,000. If Device Default is selected, security level configured on BioEntry
Smart device is used.
To issue all-time pass card (bypass card), you can choose bypass card option.
Note : What is bypass card? Device authorizes a user with a card without
fingerprint authentication process.