User's Manual

BioEntry Smart/Pass BioEntry Installation Guide 21
Copyright © 2005 by Suprema Inc. http://www.supremainc.com
Parameter Symbol Min Typ. Max Units
Supply current I
DD
200 500 mA
Wiegand Input Port Symbol Min Typ. Max Units
High level input voltage V
WIH
3.3 12 V
Low level input voltage V
WIL
-0.3 2.0 V
Wiegand Output Port Symbol Min Typ. Max Units
High level output voltage V
OH
5.0 V
Low level output voltage V
OL
0.0 V
Current source/drain I
O
-1/20 mA
4.3. Smart card specifications
Parameter Value
Antenna type PCB loop antenna (60mm x 57mm)
Connection with transceiver Permanent
Manufacturer / Model Dual I, DE-KTFMI
Operating Frequency Range 13.553 ~ 13.567MHz
Duty cycle 100%
4.4. Material information
Component Material / Model Manufacturer
PCB FR-4, Doosan Electronics
Enclosure ABS, HF-380 LG Chem, Ltd.
Battery CR2032 Hitachi Maxell, Ltd.
4.5. RTC battery specification
Parameter Value
Model CR2032
Manufacturer Hitachi Maxell, Ltd.
Nominal Voltage 3 V
Nominal Capacity 210mAh
UL Recognition MH12568(N)
Temp. range -20 ~ +85°C