User's Manual
20
ⒸCopyright 2006 Suprema Inc.
Operation mode setting
n If you select Mode on initial Admin menu, following menus
appear on the display.
After installation, it is necessary to select an operation modesuitable for its usage.
l Setting : Finger or PIN / Finger Only / Pin Only / Card Only
l After entering ID on 1:1 mode, set whether you will use fingerprint,
PIN, or either for authentication. In case of card, using card only
enables users to access just by placing the card.
l Set schedules to apply the above 1:1 mode.
l Select “All Time”, “No Time” or a specific schedule set by
BioAdminprogram
l Setting: Auto / OK/T&A Key / Disabled
l Auto : Fingerprint sensor is always on standby. So, if a finger is
placed, identification starts automatically.
l OK/T&A key : After pressing OK key or T&A function key,
fingerprint sensor is turned on to scan a fingerprint.
l Disabled : 1:N identification is not used. In order to enhance the
security level of your system, you can use 1:1 mode in which users
should enter their ID first.
l Set schedules to apply the above 1:N mode
l Select “All Time”, “No Time” or a specific schedule set by
BioAdminprogram
1:1 Mode
1:1 Time
For Administrators -Basic Functions
Mode
◀ Finger or PIN ▶
1:1 Mode
1:1 Time
1:N Mode
1:N Time
Dual
Dual Time
T&A
◀ All Time ▶
◀ Auto ▶
◀ All Time ▶
◀ Not Use ▶
◀ All Time ▶
◀ Auto ▶
F1
More
1:N Mode
1:N Time