User's Manual

43
Copyright 2006 Suprema Inc.
I/O Setting
n If you select I/O on device menu and click Input, following
menus appear on display.
Change various settings for I/O.
l Setting : Disabled/Exit/Wiegand User ID/Wiegand Card ID/Generic
Input/Emergency Open/Alarm Off/Reset/Lock System
l In case of using the input port for RTE(exit button), select Exit.
l In case of using input as Wiegand User/Card ID, input 0 and input
1 are set as Wiegand User/Card ID.
l Generic Input : general input. Can be configured with output.
l Emergency Open : All relays for doors are turned on for door open
l Alarm Off : All relays are turned off to release alarm
l Reset : System reset
l Lock System : the device gets locked. Can be relasedwith master
password only.
l Minimum duration of input signal to decide validity
l Set N/O (Normal Open) or N/C (Normal Close)
l Setting : None/Lock System/Generic Input/Emergency Open/Alarm
Off/Reset
l Tamper switch is turned on when a housing(case) of BioStation is
opened. If the setting is in Lock System, the device is
automatically locked when a tamper switch is on for security.
l [Note] Once BioStation is locked, lock can be released only when
the master password is entered. It cannot be released by
administrators fingerprint.
Input 0/1
Input Type 0/1
Duration 0/1(ms)
Tamper S/W
For Administrators -Advanced Functions
I/O
Disable
Input 0
Duration0(ms)
Input Type 0
Input 1
Duration1(ms)
Input Type 1
Tamper SW
0
N/O
Disable
0
N/O
None
I/O
Input
Output