User Manual

36
Copyright 2006 Suprema Inc.
Fingerprint Setting
z Setting : Normal/Fast/Fastest
z Using 1:N mode with more than hundreds of users, identification may take somewhat longer. In this
case, you can change the fast mode to Fast or Fastest. By doing so, identification speed becomes
faster in sacrifice of a little higher FRR.
z Setting: Weak/Normal/Strict
z Quality level decides the strictness of quality check of the input images. With a strict quality level, the
device may reject a low quality input fingerprint more.
z Setting : Visible/Invisible
z Proper enrollment can be induced by showing the image of the entered fingerprint on LCD screen upon
enrollment.
z Setting : 0(min)/1/2/3/4/5/6/7(max)
z Set sensitivity of fingerprint sensor in a capture of a fingerprint. At a high sensitivity level, it is easier
and faster to capture a fingerprint. On the other hand, at a low sensitivity level, the image quality of the
captured fingerprint can be more stable.
z In normal applications, maximum level is recommended. If the recognition is not satisfactory for wet
fingerprints, reducing sensitivity may solve the problem.
z Setting : 1/2/…/10/…/19/20
z Set standby time for fingerprint enrollment. If a user does not place a finger within the time, a timeout
message appears on the display.
z Setting : Not Use / Use
z Shows whether the BioStation is curretnly using the template encryption or not. Encryption can not be
set on the device itself, but should be set using BioAdmin program on PC.
Fast Mode
Quality
View Image
Sensitivity
Timeout(Sec)
For Administrators - Advanced Functions
Encryption