I/O Setting
If you select I/O on device menu, following menus appear on
display.
I/O
Disabled
Input 0
Input 1
Output 0
Output 1
Duration(ms)
Tamper SW
Disabled
Disabled
Disabled
1000
None
Change various settings for I/O.
z Setting : Disabled/Exit/Wiegand
z In case of using the input port for RTE(exit button), select Exit.
z In case of using input as Wiegand, input 0 and input 1 are set as
Wiegand.
z Setting: Disabled/Duress/Tamper SW/Auth Success/Auth
Fail/Wiegand
z Can send outputs for various events.
z In case of using output as Wiegand, output 0 and output 1 are set
as Wiegand.
z Set the cycle of output signal. Default is 1sec (1000ms).
z Setting : None/Lock System
z Tamper switch is turned on when a housing(case) of BioStation is
opened.
z If the setting is in “Lock System”, the device is automatically locked
when a tamper switch is on.
z This can be useful in security when an intruder opens the housing
of BioStation to enter a building.
z [Note] Once BioStation is locked, lock can be released only when
the master password is entered. It cannot be released by
administrator’s fingerprint.
Input 0 & Input 1
Output 0 & Output 1
Duration(ms)
Tamper S/W