www.supremainc.com USER GUIDE BioStation L2 English Version 1.00 EN 102.00.BSL2 V1.
Contents Safety Instructions .......................................................................................... 4 Introduction ...................................................................................................... 6 Components ...................................................................................................................................................6 Name and function of each part ................................................................................
Product Specifications ................................................................................. 25 Dimensions ...................................................................................................................................................26 FCC compliance information ...................................................................... 27 Appendices ..................................................................................................... 28 Escape clause .........
Safety Instructions Safety Instructions Observe the following instructions to use the product safely and prevent any risk of injury or property damage. Warning Noncompliance of instructions could lead to serious injury or death. Installation Do not install the product in a place with direct sunlight, moisture, dust, or soot. • A fire or electric shock may occur. Do not install the product in a place with heat from an electric heater. • A fire or electric shock may occur due to overheating.
Safety Instructions Operation Do not drop the product or apply an impact to the product. • A product failure may occur. Manage the password with care not to disclose it to others and change the password periodically. • Otherwise, illegal intrusion may occur. Do not press the buttons on the product forcibly or using a sharp tool. • A product failure may occur. Be careful not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances.
Introduction Introduction Components PVC anchor (2 EA) BioStation L2 Wall bracket Connection cable (2 pins 1 EA, 3 pins 1 EA, 4 pins 4 EA) Ferrite core (1 EA) 120 Ω resistor (1 EA) Drilling template Diode (1 EA) Fixing screw (2 EA) Quick guide Note • Components may vary according to the installation environment. • For additional content regarding product installation, access the Suprema website (www.suprema.co.kr) and view the installation guide.
Introduction Name and function of each part LCD screen Function button Keypad ESC button OK button Fingerprint authentication unit RF card authentication unit TTL input (4 pins) Ethernet Power supply (2 pins) Relay (3 pins) RS-485 (4 pins) Wiegand input/output (4 pins) Speaker Name Description LCD screen Provides UI for operation. Function button Used for the T&A Key, changing a letter, or entering a space. Keypad • • 0 ~ 9: Used for entering a number or letter.
Introduction Cables and connectors Power Pin Name Color 1 PWR +VDC Red (white stripe) 2 PWR GND Black (white stripe) Pin Name Color 1 RLY NO White 2 RLY COM Blue 3 RLY NC Orange Pin Name Color 1 485 TRXP Blue 2 485 TRXN Yellow 3 485 GND Black 4 SH GND Gray Pin Name Color 1 TTL IN0 Red 2 TTL IN1 Yellow 3 TTL GND Black 4 SH GND Gray Pin Name Color 1 WG D0 Green 2 WG D1 White 3 WG GND Black 4 SH GND Gray Relay RS-485 TTL input Wiegand input
Introduction Ethernet Pin Name Color 1 ENET RXN Yellow 2 ENET RXP Green 3 ENET TXN Red 4 ENET TXP Black 9
Introduction How to enroll a fingerprint correctly In order to improve the fingerprint authentication rate, enroll the fingerprint correctly. BioStation L2 can recognize a fingerprint even if the angle and position of a user's fingerprint input change. If you enroll a fingerprint with attention to the following matters, the authentication rate can be improved.
Admin Menu Admin Menu All Menus 1 2 Press ESC and authenticate with the Admin level credential. Select the desired menu. Note • If the administrator has not been designated, the menu screen will be displayed when you press ESC.
User User Registering user information The user information including fingerprints can be registered. 1 2 3 Press ESC and authenticate with the Admin level credential. Select USER > Add User, then press Select the desired item, then press and set or . When you press OK, the user information will be registered. • User ID: Enter the user ID you wish to register. Enter the desired ID using the number keypad, then press OK. A number between 1 and 4294967295 can be entered for ID.
User Modifying user information User Management or Administrator can modify the registered user information. A fingerprint or card can be added, and PIN and level can be modified. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select USER > Search User, then press . Select your search terms. You can search for a user by All, User ID, User Name, Fingerprint, or Card. . Modify the information by referring to Registering user information.
Authentication Authentication Mode Fingerprint Mode You can set the schedule to be used for each authentication method using a fingerprint. 1 2 3 Press ESC and authenticate with the Admin level credential. Select AUTHENTICATION > Auth Mode > Fingerprint Mode, then press Select the desired item and set the schedule by pressing • . : Mode to use a fingerprint only. • 4 or . + : Mode to authenticate with a fingerprint and then enter a PIN. To save settings, press OK.
Authentication Note • A schedule can be set in BioStar 2. If there is no set schedule, only Not Used and Always can be selected. • For detailed contents regarding setting a schedule, refer to BioStar 2 Administrator's manual. ID Mode You can set the schedule to be used for each authentication method using ID. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select AUTHENTICATION > Auth Mode > ID Mode, then press . Select the desired item and set the schedule by pressing .
Authentication 4 To save settings, press OK. Note • When Use is set for Job Code, you can change the user job code. You can select the desired job code by pressing OK long and authenticating. Fingerprint You can change settings regarding the fingerprint authentication. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select AUTHENTICATION > Fingerprint, then press . Select the desired item and then change the settings by pressing or .
Authentication Server Matching When you set Server Matching, the user authentication is not carried out in the device, but rather in BioStar. Server Matching can be useful when there is a large amount of user information in the device or you do not wish to publicly expose the device where user credential information is saved. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select AUTHENTICATION > Server Matching, then press Change the settings by pressing or . .
Display & Sound Display & Sound You can change the display and sound settings of the device. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select DISPLAY & SOUND, then press . Select the desired item and then change the settings by pressing or . • • • Home Screen: Change the style of the home screen. Backlight Timeout: Set the time (second) to turn off the lighting of LCD screen. Menu Timeout: Set the time (sec) for the menu screen to disappear automatically.
Device Device Date & Time You can set date and time. Set the date and time accurately in order to collect accurate log data. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select DEVICE > Date & Time, then press . Select the desired item and then change the settings by pressing or . • • • Date: Check the current date. To modify it directly, set Disabled for Time Sync. Time: Check the current time. To modify it directly, set Disabled for Time Sync.
Device Memory Info You can view the status of memory usage. 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select DEVICE > Device Info, then press . View the memory usage status of the device. To return to the previous screen, press ESC. Restart Device You can restart the device. 1 2 3 Press ESC and authenticate with the Admin level credential. Select DEVICE > Restart Device, then press . To restart the device, press OK. To cancel, press ESC.
Network Network Network Settings You can change the network settings of the device. Ethernet 1 2 3 4 Press ESC and authenticate with the Admin level credential. Select NETWORK > TCP/IP, then press . Select the desired item and then change the settings by pressing or . • Port: Set the device port. • • • DHCP: Set whether or not to use DHCP. If Disabled is set, the user can modify Port, IP Address, Gateway, or Subnet Mask. IP Address: View the IP address of the device.
Network Serial Settings RS-485 1 2 Press ESC and authenticate with the Admin level credential. Select NETWORK > RS-485, then press • • 3 . Mode: Select the RS-485 mode. Baud Rate: Select the desired baud rate. To save settings, press OK. .
Event Log Event Log Search Log You can set a condition and search a log. 1 2 3 4 5 Press ESC and authenticate with the Admin level credential. Select EVENT LOG.> Search, then press . Select the desired item and then change the settings by pressing To return to the previous screen, press ESC. You can delete all saved logs. Press ESC and authenticate with the Admin level credential. Select EVENT LOG > Delete All, then press . To delete all logs, press OK. To cancel, press ESC.
Troubleshooting Troubleshooting Checklist before reporting a failure Category Power Problem The power is being supplied but the device does not operate. I lost my PIN. PIN I entered my PIN and pressed the OK button, but I still cannot open the door. The fingerprint has been enrolled but fingerprint authentication cannot be done smoothly and errors occur frequently. Fingerprint Suddenly fingerprint authentication cannot be done. Door Lock The door cannot be locked when I close the door.
Product Specifications Product Specifications Category Credential General Fingerprint Capacity Interface Electrical Feature Specification Biometric RF Option Fingerprint 13.
Product Specifications Dimensions (Unit: mm) 34 201 71 171.
Appendices Appendices Escape clause • The information in this manual is provided with regard to the Suprema's products. • The right to use is acknowledged only for products included in the terms and conditions of the sales agreement guaranteed by Suprema. The right of license to other intellectual property rights not discussed in this manual is not acknowledged.
www.supremainc.com www.supremainc.