For increased energy efficiency, some water
heaters have been supplied with two 24”
sections of pipe insulation. Please install the
insulation, according to the illustrations above,
that best meets your requirements.
Typical vertical piping arrangement
Typical horizontal piping arrangement
Heat Trap
Hot and Cold Pipe Insulation Installation
For increased energy efficiency, some water
heaters have been supplied with factory installed
3/4” NPT heat traps in the hot outlet line and
cold water inlet line.
These heat traps may require a minimum of
one (1) 90° 3/4” NPT elbow and may require
an additional 90° 3/4” NPT elbow or a 3/4”
coupling depending on your installation needs.
See Illustration of nipples and heat traps on page
23.
For increased energy efficiency, this water
heater has been supplied with a 2 3/8” section
of T&P insulation. Please install the insulation
as shown below.
Typical Top Connect T & P Arrangement.
T&P Insulation Installation
Typical Side Connect T & P Arrangement.
Slip the insulation cover over the T&P Valve
through the center hole and align the hole in the
side with the opening of the T&P Valve.
Ensure the T&P Valve opening is not obstructed
by the insulation.