Instruction Manual
INSTALLATION OF NATURAL GAS PILOT VALVE (cont.)
E. Connect the two 3/8" Street Elbows (Part #17) and screw the 3/8" Locknut (Part #16) down on the male
threads of the elbow. Place the hole of the Heat Shield (Part #15) over the elbow and slide it down against
the locknut. Apply pipe compound to the male threads of the elbow and attach it to the control valve.
(See Figure 3)
IMPORTANT: Be sure to turn the pilot adjust screw with a screwdriver two full turns in a
counter-clockwise
direction to enable pilot operation. (See Figure 3)
F. Attach the 3/8" Natural Gas Orice (Part #20a or #20b) through the Burner Pan to the Burner Bar using
the 3/8" Locknut supplied only with Dual and Topside Burner log sets. When installing a single burner log
set, a 3/8" locknut is not used. Be sure the small drill hole on the 3/8" Natural Gas Orice is facing
the gas control valve and the large hole is facing the burner pan. (See Figure 4)
G. Using pipe compound, connect the 3" Nipple to the Street Elbow attached to the valve assembly and to the
3/8" Female Elbow. Connect the 3/8" Female elbow, which is now connected to the entire valve assembly,
to the Burner Orice using pipe compound. (See Figure 4)
H. The valve assembly can be rotated to better conceal the controls. Simply rotate the entire valve assembly
by turning the top 3/8" Street Elbow with a wrench. (See Figure 5)
I. Attach Pilot Burner Assembly (Part #7) to the Pilot Bracket (Part #8) using the two bolts (Part #10) and two
nuts (Part #11). See Figure 1A on the previous page. Carefully bend the Pilot tubing (Part #6) when
attaching the Pilot Burner Assembly to the Burner Pan. Care should be taken not to kink the tubing which
would restrict gas ow to the Pilot Burner.
NOTE: The Pilot Bracket utilizes four mounting holes for adjustment of the Pilot Burner Assembly should
your installation require repositioning. Repositioning of the Pilot Burner
Assembly may be necessary if the log set is experiencing intermittent
shutdown. Shutdown is caused by overheating of the Pilot Burner
Assembly by the main burner ame. If shut down is occurring, move
the Pilot Burner Assembly over to the next mounting hole so that only
the tips of the Pilot Burner Assembly are hanging over the Burner Pan.
Only one Mounting Screw (Part #10) will be used in this application.
J. Place the assembled Burner Pan with the Gas Control Valve in the
center of the replace.
K. Connect the 1/2" gas supply line from the replace to the 3/8" Straight
Flared tting (Part #4) with the 3/8" Flared Tubing supplied with the gas
log set. Refer to the General Installation Instructions section titled
“Connecting Gas Supply to Burner Pan” for full instructions.
L. Test connections for leaks with soapy water. Retighten if necessary,
and retest the connections to determine if any other leaks are present.
M. Refer the General Installation Instructions for Granule, Ember, Grate
and Log placement.
Figure 5
Figure 3
Figure 4
SINGLE, DUAL & TOPSIDE SYSTEMS (cont.)