User Manual

23
Troubleshooting Guide
Problem Possible Solution
Low heat, LP gas
The propane regulator assembly incorporates an excess flow
device designed to supply the grill with sufcient gas ow under
normal conditions, yet control excess gas ow.
Rapid changes in pressure can trgger the excess ow device,
providing a low ame and low temperature. If the tank valve is
turned open to allow gas ow while a burner valve is open, the
surge of pressure will cause the device to activate. The device
will remain closed until the pressure is equalized. This should
occur within 5 seconds.
To ensure this does not cause difculty in lighting the grill, follow
these instructions:
1. Make sure all burner valves are "OFF".
2. Open the tank valve and wait 5 seconds.
3. Light the burner one at a time following the lighting
instructions.
Low heat, natural gas
Gas pressure is affected by gas line and length of gas line from
house gas line. Follow the recommendations in the chart below.
Low heat generated with
knob in "HI" position
1. Make certain the problem is isolated to only one burner. If it
appears so, clean the orice and the burner, clearing ports of
any obstruction.
2. Check for a bent or kinked fuel hose.
3. Make sure the air shutter is properly adjusted.
4. Check for proper gas supply and pressure.
5. Pre-heat the grill for full 15 minutes.
6. If using LP gas, check for an empty tank.
From House to Grill
Distance Tubing Size
Up to 25' 3/8" diameter
26'-50' 1/2" diameter
51'-100'
2/3" of run 3/4"
1/3" of run 1/2"