User's Guide

SureCall | 48346 Milmont Dirve, Fremont CA 94538 | 1-888-365-6283 | sales@surecall.com
18
CHAPTER 5: Conguration & Testing
The Force5 has nine dipswitches. Below is an image of the dipswitches and the frequency bands
they utilize for attenuation. Next to the image is ageneral attenuation guide.
DIP Switches
1) AWS-UL (2100 Mhz) Dip switches control AWS uplink (switch 1-5)
2) AWS-DL (2100 Mhz) Dip switches control AWS downlink (switch 1-5)
3) PCS-UL (1900 Mhz) Dip switches control PCS uplink (switch 1-5)
4) PCS-DL (1900 Mhz) Dip switches control PCS downlink (switch 1-5)
5) LTE707-UL (707 Mhz) Dip switches control LTE uplink (switch 1-5)
6) LTE-DL (707 Mhz) Dip switches control LTE downlink (switch 1-5)
7) LTE781-UL (781 Mhz) Dip switches control LTE uplink (switch 1-5)
8) CELLULAR-UL (800 Mhz) Dip switches control Celluar uplink (switch 1-5)
9) CELLULAR-DL (800 Mhz) Dip switches control Celluar downlink (switch 1-5)
Switch 1 (1dB) + Switch 2 (2dB) = 3dB attenuation
Switch 1 (1dB) + Switch 2 (2dB) + Switch 3 (4dB) = 7dB attenuation
Switch 1 (1dB) + Switch 2 (2dB) + Switch 3 (4dB) + Switch 4 (8dB) = 15dB attenuation
Switch 1 (1dB) + Switch 2 (2dB) + Switch 3 (4dB) + Switch 4 (8dB) + Switch 5 (16dB) = 31dB attenuation
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5
1dB 2dB 4dB 8dB 16dB
Conguration and Testing