LED INDICATORS
Note: Bars are not always a reliable measure of signal. The best way to conrm signal coverage is the ability to place and
hold a call.
Only the presence of a RED/YELLOW ash indicates the presence of an unresolved issue.
Important: The booster gain dials should remain at maximum level and only reduced if other recommended actions do not
resolve the issue.
LED Condition Status/Resolution
Initializing on
Power-up
All control lights ash RED & YELLOW for 5 seconds then off for 5 minutes.
GREEN SOLID Normal Operation
GREEN
FLASHING
Normal Operation.
YELLOW SOLID Normal Operation, Sleep Mode
YELLOW
FLASHING
Slowly
AGC has detected Insufcient separation between the inside and outside antenna automatically reduced
gain by 1 - 10 dB for the indicated frequency band.
This may be unavoidable in some situations where distance cannot be achieved.
After 5 minutes the frequency control light will return to SOLID GREEN
YELLOW
FLASHING
Quickly
AGC has detected signicant antenna isolation issues causing a reduction in gain between 10 and 20
dB for the indicated frequency band(s).
Adjustments should be made to improve your booster’s performance by following suggested methods
below.
After 5 minutes the frequency control light will return to SOLID GREEN
RED / YELLOW
FLASHING
Alternately
Extreme gain reduction (greater than 20 dB) resulting from insufcient antenna separation.
The frequency band has been disabled.
Adjustments are required to resolve condition.
RED SOLID Indicates the frequency band is manually turned off.
Keep in mind, identifying the setup that yields the best possible results for your environment will come from testing --