Measure the exterior width of the window/door, including any brick
mold, and cut the DrainShield
TM
to that measurement. Check fit with
end caps before gluing. Remove any labels from contact surfaces.
Apply Wet-R-Dry
PVC cement to contact
surfaces on both End Caps and
DrainShield
TM
(shaded area).
Slide End Caps fully in
place. Wipe excess PVC
cement. Hold glued parts
for 1 min for PVC cement
to dry.
Check the fit with end caps before gluing them. See Sill
Pan Assembly DETAIL on page 3.
Weep Holes
SureSill
TM
Channel Plate
End Cap
End Cap
SLOPED SILL PAN ASSEMBLY
Apply Wet-R-Dry
TM
PVC cement to contact
surfaces on both End Caps and Channel Plate
(shaded area).
Slide End Caps fully in
place. Wipe off excess
PVC cement.
Page 1 of 3
SAF Henkel/OSI BUTYLFLASH;