Operation Manual
Table Of Contents
- 1. Safety instructions
- 2. Application
- 3. Features
- 4. Technical Data
- 5. Dimensional drawing
- 6. Installation considerations
- 7. Inlet and Outlet sections
- 8. Sensor Installation
- 9. Sensor signal outputs
- 10. Sensor display (option)
- 11. Service App—S4C-FS
- 12. Calibration
- 13. Maintenance
- 14. Disposal or waste
- 15. Warranty
- Appendix A Analogue output
- Appendix B Modbus communication example
- Appendix C LRC and CRC calculation
5. Dimensional drawing
Pipe
nominal
size
inch(DN)
L
total
length
[mm]
L1
inlet
length
[mm]
H
total
height
[mm]
H1
from pipe
center to
casing top
[mm]
Flange (EN 1092-1
PN40)
ØD
(mm)
ØK
(mm)
n x ØL
(mm)
S 421-1/2” 1/2”/
(DN15)
300 210 234.2 186.7 95 65 4xØ14
S 421-3/4” 3/4”/
(DN20)
475 275 239.2 186.7 105 75 4xØ14
S 421-1” 1”/
(DN25)
475 275 244.2 186.7 115 85 4xØ14
S 421-1 1/4” 1 1/4”/
(DN32)
475 275 256.7 186.7 140 100 4xØ18
S 421-1 1/2” 1 1/2”/
(DN40)
475 275 261.7 186.7 150 110 4xØ18
S 421-2” 2”/
(DN50)
475 275 269.2 186.7 165 125 4xØ18
S 421-2 1/2” 2 1/2”
(DN65)
475 275 287.1 194.6 185 145 8xØ18
S 421-3” 3”/
(DN80)
475 275 301 201.0 200 160 8xØ18
S 421 11