3.5.6. Calibrating wireless speed and distance sensor
To calibrate the wireless speed and distance sensor, first
cover a known distance using the stopwatch. Then
complete the following steps:
1.In the Speed /Distance menu scroll to Spd Sens and
press ENTER.
2.Press UP/DOWN to select Calibrate.
3.Set the covered distance with UP/DOWN.
4.Press ENTER to finish calibration. The device
calculates the calibration and displays the calibration
factor on the second row of the display.
Alternatively, you can provide the calibration factor
manually by scrolling with the UP/DOWN buttons.
More info on calibrating your wireless speed and
distance sensor can be found in the manual for the
wireless speed and distance sensor.
3.5.7. pair
This function is identical to the Pair function described section 3.4.8. Pair.