SDS

Product Name: EXXSOL D60(S) FLUID
Revision Date: 18 Dec 2015
Page 12 of 17
______________________________________________________________________________________________________________________
Serious Eye Damage/Irritation: Data
available.
May cause mild, short-lasting discomfort to eyes. Based on test
data for structurally similar materials. Test(s) equivalent or similar
to OECD Guideline 405
Sensitisation
Respiratory Sensitization: No end point data
for material.
Not expected to be a respiratory sensitizer.
Skin Sensitization: Data available.
Not expected to be a skin sensitizer. Based on test data for
structurally similar materials. Test(s) equivalent or similar to OECD
Guideline 406
Aspiration: Data available.
May be fatal if swallowed and enters airways. Based on
physico-chemical properties of the material.
Germ Cell Mutagenicity: Data available.
Not expected to be a germ cell mutagen. Based on test data for
structurally similar materials. Test(s) equivalent or similar to OECD
Guideline 471 473 474 476 478 479
Carcinogenicity: Data available.
Not expected to cause cancer. Based on test data for structurally
similar materials. Test(s) equivalent or similar to OECD Guideline
453
Reproductive Toxicity: Data available.
Not expected to be a reproductive toxicant. Based on test data for
structurally similar materials. Test(s) equivalent or similar to OECD
Guideline 414 421 422
Lactation: No end point data for material.
Not expected to cause harm to breast-fed children.
Specific Target Organ Toxicity (STOT)
Single Exposure: No end point data for
material.
Not expected to cause organ damage from a single exposure.
Repeated Exposure: Data available.
Not expected to cause organ damage from prolonged or repeated
exposure. Based on test data for structurally similar materials.
Test(s) equivalent or similar to OECD Guideline 408 413 422
OTHER INFORMATION
For the product itself:
Vapour concentrations above recommended exposure levels are irritating to the eyes and the respiratory tract, may
cause headaches and dizziness, are anaesthetic and may have other central nervous system effects. Prolonged
and/or repeated skin contact with low viscosity materials may defat the skin resulting in possible irritation and dermatitis.