SDS

Product Name: EXXSOL D60(S) FLUID
Revision Date: 18 Dec 2015
Page 5 of 17
______________________________________________________________________________________________________________________
Inappropriate Extinguishing Media: Straight streams of water
FIRE FIGHTING
Fire Fighting Instructions: Evacuate area. Prevent run-off from fire control or dilution from entering streams,
sewers or drinking water supply. Fire-fighters should use standard protective equipment and in enclosed
spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to
protect personnel.
Unusual Fire Hazards: Combustible.
Hazardous Combustion Products: Incomplete combustion products, Oxides of carbon, Smoke, Fume
FLAMMABILITY PROPERTIES
Flash Point [Method]: 61C (142F) - 66C (151F)
Flammable Limits (Approximate volume % in air): LEL: 0.7 UEL: 5.3
Autoignition Temperature: >200C (392F)
SECTION 6
ACCIDENTAL RELEASE MEASURES
NOTIFICATION PROCEDURES
In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable
regulations.
PROTECTIVE MEASURES
Avoid contact with spilled material. Warn or evacuate occupants in surrounding and downwind areas if
required, due to toxicity or flammability of the material. See Section 5 for fire fighting information. See the
Hazard Identification Section for Significant Hazards. See Section 4 for First Aid Advice. See Section 8 for
advice on the minimum requirements for personal protective equipment. Additional protective measures may be
necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders.
For emergency responders: Respiratory protection: half-face or full-face respirator with filter(s) for organic