User's Manual

Doc. No. 702202-252-01 rev. 00
Page 8 of 42
Swarm®S2 Installation and User Manual
Last updated 2021-03-02
by Harald Sleire
© Sensorlink Swarm AS 2021
5.2 The Swarm S2 ultrasound sensor variants
The UT sensors are contact probes with direct contact to the pipe.
Product
Main features
Illustration of unit
Swarm® S2
LT
Ultrasound
Sensor
Body in aluminium
Deployment kit in 304SS
Contain 1 UT sensor + 1 temp sensor.
Cable: 1-5m standard 4wire cable with
connectors
Metal loss capability better than
10µm*
Temperature Range -40°C to +150°C
Swarm® S2
HT
Ultrasound
Sensor
Body and deployment kit in 304SS
Delay: line 25mm
Cable: 300mmMIMS + 2m R316
(variable extensions available)
SMA Connector
Metal loss capability better than
20µm*
Temperature Range +150°C to +380°C
Swarm® S2
UHT
Ultrasound
Sensor
Body and deployment kit in 304SS
Delay: line 75mm
Cable: 300mmMIMS + 2m R316
(variable extensions available)
SMA Connector
Metal loss capability better than
30µm*
Temperature Range +350°C to +550°C
* Metal loss capability is defined as the system’s ability to distinguish wall thickness variations measured at the same location and
temperature over time (repeatability).
Table 4 Swarm S2 Sensor variants