Operation Manual

Occupational safety
The operating mode Occupational safety can be activated or deactivated in the menu.
If Occupational safety is activated the function Deadman-Detection and Accident-Detection are
activated, too.
Deadman-Detection
If the terminal is for approx. 30 seconds in horizontal position without any movement it starts a
pre-alarm with a count down timer. Without any reaction of the user during the count down an
emergency call will be sent out and on the display Emergency call initiated! appears
During the next approx. 20 seconds the emergency call is sent out to the control centre. After
finishing the transmission the display shows Emergency call sent.
In case the confirmation key <OK> is pressed during the count down the emergency call will be
aborted. The display shows Emergency call aborted. The emergency call can be aborted even the
key lock is active.
15
091265_eng-TRIO DE955.qxd:45331_d-Bedanl.qxd 22.06.2009 13:11 U