Accident-Detection
If the terminal falls down of approx. 80 cm, it starts a pre-alarm with a count down timer. With-
out any reaction of the user during the count down an emergency call will be sent out and on the
display Emergency call initiated! appears.
During the next approx. 20 seconds the emergency call is sent out to the control centre. After
finishing the transmission the display shows Emergency call sent.
In case the confirmation key <OK> is pressed during the count down the emergency call will be
aborted. The display shows Emergency call aborted. The emergency call can be aborted even the
key lock is active.