Model: AV-1330 HD Video Conferencing Camera User Manual V1.6 Please Read this User Manual throughout before using. www.avipas.com.
Preface Thanks for using this HD Video Conferencing Camera. This manual introduces the function, installation and operation of the HD camera. Prior to installation and usage, please read the manual thoroughly. Precautions This product can only be used in the specified conditions in order to avoid any damage to the camera: Don’t subject the camera to rain or moisture. Don’t remove the cover. Otherwise, you may get an electric shock. In case of abnormal operation, contact the authorized engineer.
Contents 1, Note ··································································································3 2, Supplied Accessories ··············································································4 3, Quick Start ··························································································5 4, Features ·····························································································8 5, Product Specification ··········································
Note Electric Safety Installation and operation must accord with electric safety standard. Caution to transport Avoid stress, vibration and soakage in transport, storage and installation. Polarity of power supply The power supply of the product is +12V, the max electrical current is 2A .Polarity of the power supply plug drawing as follows. Careful of installation Do not grasp the camera head when carrying the camera. Don’t turn camera head by hand. Doing so may result in mechanical damage.
Supplied Accessories When you unpack, check that all the supplied accessories are included: Camera ...................................... 1 AC power adaptor ....................... 1 Power cord .................................. 1 VISCA cable ............................... 1 Remote controller........................ 1 User manual ..............................
Quick Start Step1.
Step2. Setting of the bottomswitches Set both of the switch1 and switch2 to ‘OFF’. That is ‘Normal Working Mode’. SW-1 SW-2 Modes 1 OFF OFF Normal Working Mode 2 ON OFF Software Update Mode 3 OFF ON Factory Debug Mode 4 ON ON None Step3. Setting of the system select switch The option of video format: VIDEO SYSTEM 0 1080p60 8 720p30 1 1080p50 9 720p25 2 1080i60 A 1080p59.94 3 1080i50 B 1080i59.94 4 720p60 C 720p59.94 5 720p50 D 1080p29.97 6 1080p30 E 720p29.
Step4. Press the Switch ON/OFF button on the rear of the camera, the power lamp light. Step5. Pan-Tilt will rotate to the maximum position of top right after the camera started, then it return to the center, the process of initialization is finished. (Note: If the position preset 0 has been stored, the position preset 0 will be called up after initialization) Step6. (Optional)If you want to restore the factory default settings, Press [MENU] button to display the OSD menu.
Features 1. Integrated 72.5 degree wide-angle lens for the first time, Optical 12x. 2. Camera provides a high performance in low illumination situations, particularly suitable for which room's lighting is not very well. 3. With maximum resolution of 1920 x 1080 and output frame rate up to 60 or 50 frames / sec, this camera provides high-definition as well as fluent video. 4.
Product Specification Model S 1080p/60, 1080p/59.94,1080p/50, 1080p/30, 1080p/29.97,1080p/25, Video Format 1080i/60, 1080i/59.94,1080i/50, 720p/60, 720p/59.94,720p/50, 720p/30, 720p/29.97,720p/25 Video Output Interface Sensor Type Sensor Pixel Lens Focus Mode Electronic shutter White Balance Backlight Compensation SNR M C 1080p/30, 1080p/29.97,1080p/25, 1080i/60, 1080i/59.94,1080i/50, 720p/60, 720p/59.94,720p/50, 720p/60, 720p/59.94,720p/50, 720p/30, 720p/29.97,720p/25 720p/30, 720p/29.
Main Unit 1. Lens 2. Sensor for the Remote Commander 3. Power lamp 4. Standby lamp 5. Bottom switches 6. Tripod screw hole 7. Fixing screw whole 8. System select switch 9. RS232 in jack 10. RS232 out jack 11. HD-SDI video jack (Optional) 12. DVI-I video jack 13. DC in 12V jack 14. Power switch 15.
IR Remote Controller Explanation 0. Standby Button Press this button to enter standby mode. Press it again to enter normal mode. (Note: Power consumption in standby mode is approximately half of the normal mode) 1. Position Buttons To set preset or call preset 2. * Button 3.
become dark. In this case, press the backlight ON / OFF button. To cancel this function, press the backlight ON / OFF button. 5. Focus Buttons Used for focus adjustment. Press [AUTO] adjust the focuses on the center of the object automatically. To adjust the focus manually, press the [MANUAL] button, and adjust it with [Focus+] (Focus on far object) and [Focus-] (Focus on near object) 6. Camera Select Buttons Press the button corresponding to the camera you want to operate with the remote controller. 7.
USE IR Remote Controller When the camera is working, you can use Move up: Press [ ] remote controller to perform panning, tilting, Move down: Press [ ] zooming and focusing, store and call back preset Move left: Press [ ] positions. Move right: Press [ ] Button Instruction: Face the camera back to front: Press [HOME] 1. In this instruction, ‘press the button’ means Press and hold the up/down/left/right button, the press and relax the two actions.
effective in full auto exposure mode) 3. Focus Control 5. Presets Set/Clear Focus Far: Press [FOCUS+] button(NOTE: Effective only in manual focus mode) Focus Near: Press [FOCUS-] button(NOTE: Effective only in manual focus mode) Press and hold the button, the action of focus continues and stops as soon as the button is released. AUTO: Change focus mode to AF, adjusting the 1. To store a preset position: The users should focus automatically.
7. Camera Selection Press [#]+[#]+[#] will erase all preset positions in the memory. 6.Recalling the Preset Press the button corresponding to the camera you want to operate. 8. Camera IR Address Set Press any of the numeric buttons 0-9directly to [*]+[#]+[F1]: Address1 recall stored preset positions and settings. [*]+[#]+[F2]: Address2 Note: [*]+[#]+[F3]: Address3 No action is executed if a relative preset [*]+[#]+[F4]: Address4 position is not stored.
RS-232CInterface Camera Windows DB-9 1.DTR 1.CD 2.DSR 2.RXD 3.TXD 3.TXD 4.GND 4.DTR 5.RXD 5.GND 6.GND 6.DSR 7.IR OUT 7.RTS 8.NC 8.CTS 9.RI Camera Mini DIN No. Function 1 DTR 2 DSR 1.DTR 1.DTR 3 TXD 2.DSR 2.DSR 4 GND 3.TXD 3.TXD 5 RXD 4.GND 4.GND 5.RXD 5.RXD 6 GND 6.GND 6.GND 7 IR OUT 7.IR OUT 7.NC 8 NC 8.NC 8.
VISCA Network Configuration 17
Serial Communication Control In default working mode, the camera is able to connect to a VISCA controller with RS232C serial interface. The parameters of RS232C are as follows: Baud rate: 2400/4800/9600 bit/s. Start bit: 1 bit. Data bit: 8 bits. Stop bit: 1bit. Parity bit: none. Pan-Tilt will rotate to the maximum position of top right after the camera started, then it return to the center, the process of initialization is finished.
VISCA Command List Part 1 Camera-Issued Messages Ack/Completion Message Command Command Packet Comments ACK z0 41 FF Returned when the command is accepted. Completion z0 51 FF Returned when the command has been executed.
Wide(Standard) 8x 01 04 07 03 FF Tele(Variable) 8x 01 04 07 2p FF Wide(Variable) 8x 01 04 07 3p FF Direct 8x 01 04 47 0p 0q 0r 0s FF Stop 8x 01 04 08 00 FF Far(Standard) 8x 01 04 08 02 FF Near(Standard) 8x 01 04 08 03 FF Far(Variable) 8x 01 04 08 2p FF Near(Variable) 8x 01 04 08 3p FF Direct 8x 01 04 48 0p 0q 0r 0s FF Auto Focus 8x 01 04 38 02 FF Manual Focus 8x 01 04 38 03 FF Auto/Manual 8x 01 04 38 10 FF p = 0(low) - 7(high) pqrs: Zoom Position p = 0(low) - 7(high) CAM_Focus CA
Down 8x 01 04 04 03 FF Direct 8x 01 04 44 00 00 0p 0q FF pq: B Gain Full Auto 8x 01 04 39 00 FF Automatic Exposure mode Manual 8x 01 04 39 03 FF Manual Control mode Shutter priority 8x 01 04 39 0A FF Shutter Priority Automatic Exposure mode Iris priority 8x 01 04 39 0B FF Iris Priority Automatic Exposure mode WDR 8x 01 04 39 21 FF WDR mode Low Light 8x 01 04 39 22 FF Low Light mode Reset 8x 01 04 0A 00 FF Up 8x 01 04 0A 02 FF Down 8x 01 04 0A 03 FF Direct 8x 01 04 4A 00 00 0p 0
Down 8x 01 04 0E 03 FF Direct 8x 01 04 4E 00 00 0p 0q FF On 8x 01 04 33 02 FF Off 8x 01 04 33 03 FF CAM_NR(2D) - 8x 01 04 53 0p FF p: NR Setting (0: OFF, level 1 to 5) CAM_NR(3D) - 8x 01 04 54 0p FF p: NR Setting (0: OFF, level 1 to 5) CAM_Flicker - 8x 01 04 23 0p FF p: Flicker Settings(0: OFF, 1: 50Hz, 2: 60Hz) Reset 8x 01 04 02 00 FF Up 8x 01 04 02 02 FF Down 8x 01 04 02 03 FF Direct 8x 01 04 42 00 00 0p 0q FF pq: Aperture Gain Reset 8x 01 04 3F 00 0p FF p: Memory Number(=0
Down 8x 01 06 01 VV WW 03 02 FF speed) Left 8x 01 06 01 VV WW 01 03 FF WW: Tilt speed 0x01 (low speed) to 0x14 (high Right 8x 01 06 01 VV WW 02 03 FF speed) Upleft 8x 01 06 01 VV WW 01 01 FF YYYY: Pan Position(TBD) Upright 8x 01 06 01 VV WW 02 01 FF ZZZZ: Tilt Position(TBD) DownLeft 8x 01 06 01 VV WW 01 02 FF DownRight 8x 01 06 01 VV WW 02 02 FF Stop 8x 01 06 01 VV WW 03 03 FF AbsolutePosition RelativePosition 8x 01 06 02 VV WW 0Y 0Y0Y0Y 0Z 0Z0Z0Z FF 8x 01 06 03 VV WW 0Y 0Y0Y0Y 0Z 0Z0
CAM_AFZone Top 8x 01 04 AA 00 FF Center 8x 01 04 AA 01 FF Bottom 8x 01 04 AA 02 FF HDMI 8x 01 04 AB 02 FF DVI 8x 01 04 AB 03 FF Direct 8x 01 04 4F 00 00 00 0p FF CAM_DVIMode CAM_ColorHue AF Zone weight select DVI output mode, default: HDMI CAM_Gamma 8x 01 04 5B 0p FF p: Color Hue setting 0h (− 7dgrees) to Eh ( +7 degrees) p: Gamma setting (0x00~0x0A) Part 3 Query Command Command Command packed CAM_PowerInq 8x 09 04 00 FF CAM_ZoomPosInq 8x 09 04 47 FF CAM_FocusAFModeInq 8x 09 04
y0 50 0B FF Iris priority y0 50 21 FF WDR y0 50 22 FF Low Light CAM_ShutterPosInq 8x 09 04 4A FF y0 50 00 00 0p 0q FF pq: Shutter Position CAM_IrisPosInq 8x 09 04 4B FF y0 50 00 00 0p 0q FF pq: Iris Position CAM_WDRStrengthInq 8x 09 04 B1 FF y0 50 00 00 0p 0q FF pq: WDR Strength CAM_LowLightLevInq 8x 09 04 B2 FF y0 50 00 00 0p 0q FF pq: Low Light Level CAM_ExpCompModeInq 8x 09 04 3E FF y0 50 02 FF On y0 50 03 FF Off CAM_ExpCompPosInq 8x 09 04 4E FF y0 50 00 00 0p 0q FF pq: Exp
vw: Socket Number VideoSystemInq IR_Receive 8x 09 06 23 FF 8x 09 06 08 FF IR_ReceiveReturn Pan-tiltMaxSpeedInq 8x 09 06 11 FF Pan-tiltPosInq 8x 09 06 12 FF CAM_AFSensitivityInq 8x 09 04 58 FF CAM_IridixInq 8x 09 04 A7 FF Color System Inq 8x 09 04 A8 FF y0 50 00 FF 1920x1080i60 y0 50 01 FF 1920x1080p30 y0 50 02 FF 1280x720p60 y0 50 03 FF 1280x720p30 y0 50 07 FF 1920x1080p60 y0 50 08 FF 1920x1080i50 y0 50 09 FF 1920x1080p25 y0 50 0A FF 1280x720p50 y0 50 0B FF 1280x720p25 y0 5
CAM_GammaInq CAM_AFZone 8x 09 04 5B FF 8x 09 04 AA FF CAM_DVIModeInq 8x 09 04 AB FF CAM_ColorHueInq 8x 09 04 4F FF CAM_AWBSensitivityInq 8x 09 04 A9 FF y0 50 0p FF p: Gamma setting y0 50 00 FF Top y0 50 01 FF Center y0 50 02 FF Bottom y0 50 02 FF DVI Mode:HDMI y0 50 03 FF DVI Mode:DVI y0 50 00 00 00 0p FF p: Color Hue setting 0h (− 7dgrees) to Eh ( +7 degrees) y0 50 00 FF High y0 50 01 FF Normal y0 50 02 FF Low 27 (0x00~0x0A)
Part 4Custom control command Command CAM_Power Function Command packed On 8x 02 16 16 16 65 FF OFF(Standby) 8x 02 16 16 16 56 FF TCL Standby 8x 01 02 75 75 01 04 FF TCL Wakeup 8x 01 02 75 75 00 03 FF TCL_Power Part 5 Comments Custom Power ON/OFF Forwarding AD DA 02 B0 01 04 AF FA Forwarding AD DA 02 B0 00 03 AF FA Customize the query command Command Command packed Inquiry Packet Comments p:Error code CAM_StatusInq 8x 02 20 01 01 FF y0 50 0p 00 0q rs 0t 0u FF q:License rs:Video format t:
Pelco-D Protocol Command List Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Up 0xFF Address 0x00 0x08 Pan Speed Tilt Speed SUM Down 0xFF Address 0x00 0x10 Pan Speed Tilt Speed SUM Left 0xFF Address 0x00 0x04 Pan Speed Tilt Speed SUM Right 0xFF Address 0x00 0x02 Pan Speed Tilt Speed SUM Zoom In 0xFF Address 0x00 0x20 0x00 0x00 SUM Zoom Out 0xFF Address 0x00 0x40 0x00 0x00 SUM Focus Far 0xFF Address 0x00 0x80 0x00 0x00 SUM Focus Near 0xFF
Pelco-P Protocol Command List Function Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8 Up 0xA0 Address 0x00 0x08 Pan Speed Tilt Speed 0xAF XOR Down 0xA0 Address 0x00 0x10 Pan Speed Tilt Speed 0xAF XOR Left 0xA0 Address 0x00 0x04 Pan Speed Tilt Speed 0xAF XOR Right 0xA0 Address 0x00 0x02 Pan Speed Tilt Speed 0xAF XOR Zoom In 0xA0 Address 0x00 0x20 0x00 0x00 0xAF XOR Zoom Out 0xA0 Address 0x00 0x40 0x00 0x00 0xAF XOR Focus Far 0xA0 Address 0x00
Menu Setting 1.MENU EXPOSURE Press [MENU] button to display the main menu Mode Auto EV On EVLevel +1 BLC Off G.Limit 7 Exposure Flicker 50Hz Color Meter Global on the normal screen,using arrow button to move the cursor to the item to be set.Press the [HOME] button to enter the corresponding sub-menu. MENU Image P/T/Z Select Item Noise Reduction Change Value Setup [Menu] Back Restore Default Mode: Exposure mode.
F2.4,F2.8,F3.4,F4.0,F4.8,F5.6,F6.8,F8.0,F9.6,F11.0, COLOR Close(Effective only in Manual, AAE mode) Shutt: Shutter value. Optional items:1/2,1/4, 1/8,1/15,1/30,1/60,1/90,1/100,1/125,1/180,1/250,1/35 0,1/500,1/725,1/1000,1/1500,1/2000,1/3000,1/4000,1 /6000,1/10000(Effective only in Manual, SAE mode) Stren: WDR strength. Optional items: 0~6(Effective WB-Mode Auto RTuning 0 BTuning 0 Sat.
items: Low, Normal, High +5 Hue: Automatic white balance is tonal, Optional Sharpness: Sharpness adjustment. Optional items: 0 ~ items:-7 ~ +7, Default 0(Effective only in Manual 15 mode) B&W-Mode: Black and white mode switch. Optional items: On, Off Flip-H:Image flipped horizontally. Optional items: 4. IMAGE On, Off Move the cursor to the Image item in the main Flip-V:Image Flip Vertical. Optional items: On, Off menu and press [HOME] button, IMAGE menu Gamma: Gamma adjust, Optional items:0.
L/R Set: Reverse setting remote control, Optional NOISE REDUCTION items: STD, REV(When set to REV, remote control NR2D-Level 4 or reverse) NR3D-Level 3 AF-Zone: Interested in focusing area, Optional items: Center, Bottom, Top D-HotPixel Off DarkDetail 1 AF-Sense: Automatic focusing sensitivity options, Optional items: Low, Normal, High 6.
Protocol: Control protocol type. Optional items: 7. SETUP VISCA,P-D,P-P Move the cursor to the Setup item in the main Address: protocol address, To be decided according menu and press [HOME] button, SETUP menu to the agreement, can be set up under the VISCA appears, as shown in the following figure.
serial address. 8. RESTORE DEFAULT Move the cursor to the Restore Default item in the main menu and press [HOME] button, RESTORE DEFAULT menu appears, as shown in the following figure. RESTORE DEFAULT Restore? No Change Value [Home] OK [Menu] Back Restore: Confirm restore factory settings. Optional items: Yes, No. Press [HOME] 3s restore factory settings.
Maintenance and Troubleshooting Camera Maintains If camera will not be used for a long time, please turn off the power switch,disconnect AC power cord of AC adaptor to the outlet. Use soft cloth or tissue to clean the camera cover. Please use the soft dry cloth to clean the lens. If the camera is very dirty, clean it with diluted neuter detergent. Do not use any type of solvents, which may damages the surface.
Control IR remote controller cannot control the camera 1. Change the battery 2. Check the camera working mode. 3. Check IR address of the Remote Commander is set correctly. Serial communication cannot control the camera 1. Check the camera working mode. 2. Check control cable is connected correctly. Copyright Notice The contents of this manual are copyrighted by our company. This document Cannot be cloned, copied or translated without the permission of the company.