Programming Instructions

SYCLOPE COOLTOUCH setting Page 21/40
Communication programming instructions
d) Internet & Web Server configuration [4731]
i. Configuration
Press to open the following screen.
Embedded Web Server WIFI ETHERNET
- Check the « WIFI » or « ETHERNET » box to activate the Embedded Web Server.
Port 8080
- If you activate the Embedded Web Server you must enter the port number of your regulator.
Press in the rectangle to open the numeric keyboard and enter the desired value.
Display locked by password
- You can enable this option to lock the web server display with a password.
Press in the rectangle to open the numeric keyboard and enter the desired value
The values that can be changed on the web page are the high and low alarms and the instructions if they
are not "OFF".
Automatic time setting
- If this option is activated, your regulator will regularly check the time on the internet using the SNTP
protocol. So, your regulator must be connected and have internet access.
INTERNET
WEB SERVEUR
Web settings
Automatic time setting
Customize NTP server # 1
Customize NTP server # 2
Embedded Web Server
WIFI
ETHERNET
Port
Programming password
8080
WIFI
ETHERNET