Installation Instructions

General use Page 32/67
Installation and starting instructions
V. General use
SYCLOPE ODITouch
®
is intended for measurement, regulation and treatment of swimming pool water.
The installation of SYCLOPE ODITouch
®
equipment is based on the principle of measurement and
regulation on the pool filter circuit.
This type of installation is recommended in the event of a single pool or multiple pool, each
with an independent filtration circuit.
Water is taken by a specific sample after the filtration engine.
The analysis chamber receives the water to be measured and transmits the parameters
of the measurement probes to the SYCLOPE ODITouch
®
regulator.
Depending on the set points set by the user, the SYCLOPE ODITouch
®
regulator
sends injection orders of the product downstream of filtration to the dosing device.
Pool
Device
Measurement cells
Sample plug
Buffer tank
Pump
Heater
Sewer
Filter