Instructions

20
e) THE DEFAULT VALUES AFTER REFRESHING
LOCATION PARAMETERS DEFAULT FUNCTIONS & VALUES
0 1 Master Code 0 0 0 0 Factory Set, Not a default value *
0 2
Super User Codes
Nil ----- User Program Required
0 3 Common User Code 1 Nil ----- User Program Required
0 4 Common User Code 2 Nil ----- User Program Required
0 5 Common User Code 3 Nil ----- User Program Required
1 0 User Codes & Cards for O/P 1 Nil ----- User Program Required
2 0 User Codes & Cards for O/P 2 Nil ----- User Program Required
3 0 User Codes & Cards for O/P 3 Nil ----- User Program Required
4 0
Visitor Codes
Nil ----- User Program Required
4 1 Duress Code for O/P 1 Nil ----- User Program Required
4 2
Duress Code for O/P 2 Nil ----- User Program Required
4 3 Duress Code for O/P 3 Nil ----- User Program Required
5 1 O/P Mode of The O/P 1 Time = 5 Sec, Momentary
5 2 O/P Mode of The O/P 2 Time = 5 Sec, Momentary
5 3 O/P Mode of The O/P 3 Time = 5 Sec, Momentary
5 5 System Real-Time-Clock Nil ----- User Program Required
5 6 Start & Stop Time Nil ----- User Program Required
6 0 Personal Safety & Lock-out Code = 1, 10 False Code/Card Lock-out 60 Sec
7 0 User Code Entry Mode Code = 2, Manual Entry Mode
7 1 Pacier Tones ON-OFF Selection Code = 1, Pacier Tone ON
7 2 O/P Operation Announcer Code = 1 Sec, Notication Beep ON
7 3 Status LED Standby Flashing ON-OFF Code = 1, Flashing Enabled
8 0 Door Forced Open Warning & Timing Code = 0, Warning Disabled
8 1 Door Propped-up Warning & Delay Code = 0, Warning Disabled
9 0 Egress Delay & Warning
Code 1 = 1, Momentary Contact without Warning
Code 2 = 0, Instant, No Delay
9 1 Door Opening Alarm & Timer Code = 0, Alarm O/P Disabled
9 2 Wiegand Output Mode Code = 1, Disabled
9 3 Wiegand Output Format Code = 1, 26-Bit
9 4 Operation Modes Code = 0, Keypad Mode
The DAP Code 2 8 2 8 and the Refreshing Code 9 9 9 9 are xed in the operating system program. It can
not be changed in any ways.