Instructions
23
2) Override The Door Lock Controlled by Output 1 (Keep Door Un-locked)
The Output 1 is usually for door lock control. In some situations, the door may require un-locked for a period of time to
allow door opening without User Code or EM Card for entry / exit convenience. This function Starts / Stops in toggle
with the following code entry.
SUPER USER CODE
# 7
---------- The Door is Un-locked, Start / Stop in Toggle
• The door is un-locked while the function is enabled.
• Do not forget to stop this function after use because the door is un-locked. Also, the system refuses the optional
functions (3) & (4) while Override function comes into effect.
• This feature is good for all the “Fail-safe electric locks”.
• “Fail-secure electric lock” requires power to keep in un-locked condition. It takes high current all the time while
the function comes into effect and may cause damage to it. This function is not recommended for Fail-secure
electric lock.
While
SUPER USER CODE
# 7 is in operation to hold the door lock open, the functions that rely
on the door sensor (such as a magnetic contact) and the User Codes for output 1 are all temporarily
suspended until
SUPER USER CODE
# 7 is keyed in again to release the door hold function.
The following are the temporarily suspended functions:
• Door Auto-relock
• Door Forced Open Warning (at Location 80)
• Door Propped-up Warning (at Location 81)
• Door Opening Alarm (at Location 91)
• Dual Keypad Inter-lock Operation
• All User Codes Including Super User Code for Output 1
• Duress Output Actuated by The Duress Code for Output 1
3) Pause The Scheduled Daily Inhibition for Output 1 (Temporarily Disable The Inhibition)
The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop times. It can be stopped
temporarily if required; such as the staff work overtime after ofce hours going into the inhibition period. This function
Starts / Stops in toggle with the following code entry. It can be done before or during the inhibition period.
SUPER USER CODE
# 8
---------- Door Lock Operation Resumes, Start / Stop in Toggle
The “INHIBIT” LED (Red) is ON in inhibition and turns to Flashing while pause is into effect.
See Programming Locations 55 & 56 for more information Daily Inhibition.