Instructions

28
(a) Key in the User Group that the User ID belongs to. “10” for Group 1, “20” for Group 2, and “30” for Group 3
(b) Key in “5” that is the Command Code for making a deletion
(c) Key in the User ID that stored the User Code, the lost EM card or the EM Card+User Code
(d) Press the # key. Two-beep conrms a valid entry and the Code and/or Card in that User ID is cleared
Delete an EM Card
10 5
Read Card
#
(a) (b) (c) (d)
(a) Key in the User Group that the EM Card belongs to. “1 0” for Group 1, “2 0” for Group 2,.and “3 0” for Group 3
(b) Key in “5” that is the Command Code for making a deletion
(c) Read the EM card. One-beep conrms the reading. Read the Card only also makes a valid deletion to the Card
working with the Common User Code or the Secondary User Code
(d) Press the # key. Two-beep conrms a valid entry. The EM Card in that User ID is cleared. Key in the User ID is not
required.
Example 6 – Clear The Whole Group of Users:
Whole group of users including the Codes and Cards can be cleared with the following command.
10 0999 #
(a) (b) (c)
(a) The User Group 1 – “10” is selected to be cleared. “20” for Group 2 & “30” for Group 3
(b) Key in the Group Deletion Command, 0 9 9 9
(c) Conrm the deletion with #. All the User Codes and Cards in Group 1 are cleared. It takes few seconds to a minute
to complete depending on the data stored.
Example 7 – Report A Duress While Using EM Card:
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User Code” or “EM Card +
Common User Code” operation, they can be used to replace the “Secondary User Code” or the “Common User Code”
to operate the specic output and report a duress alarm event. Programming is not required. The system has this
function automatically while Duress Code exists.
Operation: (while the system is in the operation mode)
Read Card Duress Code
#
(a) (b) (c)
(a) Read the EM card. Two-beep conrms the reading and 30 seconds waiting time is given for entry of the Duress
Code, the Amber LED keeps ashing
(b) Key in one of the Duress Codes for the specic output (the Code programmed in “Location 41, 42, or 43” for Output
1, 2 and 3 respectively)
(c) Conrm it with the # key. The specic Output activates in a normal way and the Duress Output also activates to
report Duress Event to an alarm system.
The Duress Event can not be reported if the operation mode is EM Card alone. It is required to key in the
Duress Code directly instead of EM card to report Duress Event.