Instructions
31
(2) DURESS CODE IDs
01 - 50 50 Duress Code IDs for The Output 1
01 - 10 10 Duress Code IDs for The Output 2
01 - 10 10 Duress Code IDs for The Output 3
0999 = Clear all the Duress Codes from the selected Location group.
Please see the programming example below for the details.
(3) THE DURESS CODES
50, 10 and 10 Duress Codes can be programmed for Output 1, 2 and 3 respectively. They are stored in their two-digit
Code ID box. When a new Code is put into the same Code ID box, the old code is replaced.
• The Duress Codes are 4-8 digits for Manual Mode code entry.
• The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
• Always set a Duress Code that is easy to remember in Panic Situation. Only one number different from the daily
used User Code is highly recommended.
• Example: User Code is 1 3 6 9, then 3 3 6 9 or 1 3 6 0 might be a good choice for the Duress Code.
• The Duress Code can also be used to replace the Secondary User Code or Common User Code in Card
reading for the Duress reporting.
(4) VALIDATION
Press # key once. Two-beep conrms the entry.
EXAMPLES:
Example 1: Set a “Duress Code” with the number of “3 3 6 9” for Output 1
41 01 3369 #
(a) (b) (c) (d)
(a) Duress Code for Output 1, (b) Duress Code ID, (c) The Duress Code, (e) Entry Conrmation
Example 2: Set a “Duress Code” with the number of “2 3 9 8 0” for Output 2
42 01 23980 #
(a) (b) (c) (d)
(a) Duress Code for Output 2, (b) Duress Code ID, (c) The Duress Code, (e) Entry Conrmation
Example 3: Delete an Output 1 “Duress Code” from Duress Code ID 01 in the memory
41 01 #
(a) (b) (c)
(a) Duress Code for Output 1, (b) The Duress Code ID, (c) Delete Conrmation