21. START & STOP TIMES FOR DAILY INHIBITION OF
OUTPUT 1 -- Location 56
Setting with start and stop times into the keypad, the real-time inhibition period for output 1 will recycle daily until the
time settings are cleared.
This function works with the real-time-clock. Set up the real-time at Location 55 is necessary.
For safety reason, the Egress Button is designed always valid. The door lock (controlled by output 1) can be opened
with it at anytime during inhibition.
LOCATION
START TIME
STOP TIME
VALIDATION
56 hh : mm hh : mm #
(1)
HOURS MINUTES
(2)
HOURS MINUTES
(3)
(4)
(1) LOCATION
Key in Location 56
(2) START TIME
HH : MM Set the real-time inhibition starting time in Hour and Minute. The allowed time gure is 00:00 – 23:59
The starting time is based on 24 hours daily with the rst two digits for hours and the last two digits for minutes.
The time in second always starts at 0 0.
(3) STOP TIME
HH : MM Set the real-time inhibition stopping time in Hour and Minute. The allowed time gure is 00:00 – 23:59
The stopping time is based on 24 hours daily with the rst two digits for hours and the last two digits for minutes.
The time in second always starts at 0 0.
(4) VALIDATION
Press # key once.
Two-beep conrms the setting.
Programming and Operation Examples:
Set the starting and stopping time for the real-time inhibition period
a) Set Inhibition Period from 12:30 PM (today) – 1:30 PM (same day) for lunch time:
56 1230 1330 #
b) Set Inhibition Period from 6:30 PM (today) – 8:15 AM (next day) for ofce close: