Instructions
46
33. WIEGAND DATA OUTPUT MODES -- Location 92
LOCATION
→
DATA OUTPUT MODES
→
VALIDATION
92 1, 2, 3 or 4 #
(1) (2) (3)
(1) LOCATION
Key in Location 92
(2) DATA OUTPUT MODES
1 --- Wiegand Data Output Disabled (Default)
No Wiegand data output
2 --- Wiegand Data Output Enabled -- Mode “A”
The keypad gives Wiegand data output ONLY for those cards and codes that have been registered in memory.
3 --- Wiegand Data Output Enabled – Mode “B”
The keypad gives Wiegand data output for ALL the cards and codes that are read; no matter they are registered or
not registered in memory.
• This mode makes the keypad to work as an independent keypad or as a server of a split-decoded keypad for door
lock actuation; and at the same time serves optional controller that utilizes the Wiegand data for different jobs.
• The keypad discriminates the registered and non-registered cards and codes with different beeps when it sends
out the Wiegand data; successful beeps for the registered cards and codes and ve beeps for the non-registers.
• The keypad follows the lock-up setting at Location 60
4 --- Wiegand Data Output Enabled – Mode “C”
This is the Reader Mode of the keypad. It gives Wiegand data output for ALL the cards and codes that are read; no
matter they are registered or not registered in memory.
• This mode makes the keypad to work as an independent keypad or as a server of a split-decoded keypad for door
lock actuation and at the same time serves optional controller that utilizes Wiegand data for different jobs.
• The keypad ALWAYS gives successful beeps when it sends out the Wiegand data after reading a card or code.
• The keypad does not follow the lock-up setting at Location 60 and disables it automatically in Mode “C” to make it
a reader to un-limitedly accept reading of cards and codes.
(3) VALIDATION
Press # key once. Two-beep conrms the entry