Instructions
58
LOCATION FUNCTION
ENTRY LIMITS & CODE
OPTIONS
CODE ENTRY
FACTORY
DEFAULT
9 2
Wiegand Data Output
Mode
DATA OUTPUT MODE
1 -- Wiegand Data Output
Disabled
2 -- Wiegand & Data Output
Enabled -- Mode “A”
3 -- Wiegand Data Output
Enabled – Mode “B”
4 -- Wiegand Data Output
Enabled – Mode “C”
92
DATA OUTPUT MODE
#
Mode = 1
Disabled
9 3 Wiegand Format
WIEGAND FORMAT
1 --- 26-Bit Wiegand Data
2 --- 34-Bit Wiegand Data
3 --- 37-Bit Wiegand Data
93
WIEGAND FORMAT
#
Format = 1
26-Bit
9 4 Operation Mode
FUNCTION MODE:
0---Keypad Mode
1---Server Mode
94
MODE
#
Mode = 0
Keypad
Mode
SYSTEM
CODES
FUNCTION CODE ENTRY RESULTS
0 0 0 0
Factory Set Master Code for User to set
system in programming Mode at the rst
time.
THIS IS NOT A PERMANENT SYSTEM
CODE & IT IS CHANGED IF A NEW
MASTER CODE IS PROGRAMMED.
0000 * *
OR
NEW MASTER CODE
* *
System in
Programming Mode
9 9 9 9
REFRESH CODE -- Refresh the system
and set all its function back to default
values.
9999 #
All programmed data
are cleared and back
to the default values
except the Master
Code
2 8 2 8
DAP CODE -- Direct access to
programming mode. Valid only in the
power-up delay period
2828 #
System in
Programming Mode
0 9 9 9
USER Codes / Cards whole group clearing
Code for the selected Location
LOCATIONS:
10--- User Group 1
20--- User Group 2
30--- User Group 3
40--- Vistor Group
41--- Duress Group 1
42--- Duress Group 2
43--- Duress Group 3
LOCATION NO.
0999 #
Whole group of
users in the selected
location are cleared
* * Exit Programming Code
**
The system back to
normal opration after
programming