Instructions

69
b) DOOR SENS
MAGNETIC
DOOR
SWITCH
With the help of a Normally Closed door position sensor
(usually a magnetic door switch) on the door to set up the
following functions:
Door Auto Relock -- The system will immediately relock
the door after a valid access has been gained to prevent
“tailgate” entries.
Door Forced-open Alarm -- The keypad will generate
alarm instantly if the door is forced to open. Enable the
function at Location 80.
Door Propped-up Alarm -- The keypad will generate
alarm if the door is left open longer than the pre-set
delay time. Enable the function at Location 81.
Inter-lock Control -- When the door is open,the
interlock output of the keypad will give a (-) command to
stop the other keypad in an inter-lock system.
Door Opening Alarm -- Door Opening Alarm is
designed for the emergency door only. It is always given
when the door is opened unless a valid user code or
card is used prior to the door is opened. Enable the
function at Location 91.
c) ALARM OUTPUT -- SET THE “K OR A” JUMPER TO “A”
ALARM CONTROL PANEL
LOW POWER
PIEZO BUZZER
24 HOUR N.O.
PROTECTION
ZONE
LED
OR
The Alarm Output switches to (-) ground in door forced to open or the door open after Egress Delay. You may use it
to turn ON an LED lamp and/ or a small buzzer to notify a guard; or connect it to a 24 hour Normally Open protection
zone of an alarm system. See Location 80 and Location 91 for more information about these functions.
Only one connection option is recommended. Make sure that the sink current does not exceed the maximum rating
of 100mA.