Instructions

71
f) OUTPUT 2
Shunting an N.C. Zone
N.C.
TO PROTECTION ZONE OF AN
ALARM CONTROL PANEL
N.C. MAGNETIC CONTACT
Put Output 2 jumper to N.O.
Use the Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an alarm system.
Set output contact to Start / Stop Mode (Programming Option 52, Output Mode=0).
Alarm System Arm-Disarm Control
REMOTE
ARM-DISARM
CONTROL NO.
OR N.C.
ALARM CONTROL PANEL
Use the (N.O.) or (N.C.) output contact to make arm-disarm control of an alarm system.
Consult your alarm control panel manual for the appropriate output contact for arm-disarm control.
Usually set output 2 to Momentary mode (Programming Option 521, Location 52, Output Mode=1) for multi station
systems and Start / Stop mode (Programming Option 520, Location 52, Output Mode=0) for single station systems.
g) OUTPUT 3 -- DOOR BELL BUTTON (DK-2882B OR D ONLY)
The output 3 of the DK-2882B or D is prepared for
triggering a low power door chime. DO NOT use it as a
high voltage power path for a door bell. The maximum
power rating of the contact is 24V DC/1 Amp.
Connect the N.O. output contact in parallel with the door
bell button.
(OPTIONAL)
ELECTRONIC
DOOR CHIME
N.O.
DOOR
BELL