Instructions
18
4) Door Open Alarm (Designed for Emergency Door):
• The Door Open Alarm is enabled by programming from keypad at Programming Location 91
• Alarm Output and Internal Siren activate
• Alarm happens in door forced to open or normal open with Egress Button
• No Alarm happens in door open with User Code or Card
5) Door Forced Open Alarm:
• The Door Forced Open Alarm is enabled by programming from Keypad at Programming Location 80
• Alarm Output and Internal Siren activate
• Alarm happens in door forced to open only
• No Alarm happens in door open with Egress Button, User Code and Card
If both alarms (4) & (5) are enabled in the programming, the system will take the longer one for alarm time.
6) Door Propped-up Warning
• The Door Propped-up Warning is enabled by programming from keypad at Programming Location 81
• The warning starts at the expiry of the propped-up delay
• The warning beep is given by the internal buzzer only
AUDIBLE & VISIBLE STATUS INDICATIONS OF THE KEYPAD
The internal buzzer and the status LED (usually the center LED or the LED named “MAINS” on the keypad) give the
following tones and signals respectively for system status:
STATUS TONES STATUS LED
In Programming Mode
Successful Key Entry
Successful Code / Card Entry
Unsuccessful Code / Card Entry
Power Up Delay
Output Relay Activation
In Standby
System Refreshing
Card or Code Was Stored In System
Keypad Link-up With Decoder Failed
Real-time-clock Stopped After Power Failure
------
1 Beep
2 Beeps
5 Beeps
Continuous Beeps
1 Long Beep
------
------
1 Long Beep
Continuous 1 Beep/1 sec
Continuous 3 Fast Beeps/5 secs
ON
1 Flash
2 Flashes
5 Flashes
Continuous Flashes
------
1 Flash / Second
Fast Flashing for 2.5 Minutes
------
------
------
* All Pacier Tones can be ON or OFF through the programming option at Location 71
** The Output Relay Activation beep can be selected through the programming option at Location 72