Instructions
21
12. PROGRAMMING & OPERATION
a) POWER-UP THE KEYPAD
The keypad gives power-up delay of 1 minute after power has been applied. It is the time frame designed for setting
the keypad to programming mode with DAP code. See the details of “DAP CODE – 2 8 2 8” below.
1. The keypad gives continuous beeps for 1 minute after power-up.
2. The power-up delay can be stopped instantly with 12# if the delay beep is found annoying and setting the
keypad to programming mode with DAP code is not required.
POWER-UP DELAY STOP
→
VALIDATION
1 2 #
3. The keypad will set itself to Normal Operation Mode automatically after the 1 minute power-up delay expired or
it is stopped with 12#.
b) SET KEYPAD IN PROGRAMMING MODE WITH MASTER CODE
It is always necessary to set the keypad in programming mode for feature programming
The keypad is in normal operation after power-up delay. Set it in programming mode with Master Code and validate
it with * *.
MASTER CODE
→
VALIDATION
0000 **
For those keypads without * button, the button is equivalent to the * button.
For the owner’s convenience in programming at the rst time, a Master Code 0 0 0 0 has been put into the
keypad before exit-factory. It is NOT a default code. For security reason, owner should program a personal
Master Code to replace it after the keypad is owned.
The Mains LED (amber) is ON after the keypad conrms it in programming mode with 2 beeps.
DO NOT turn off power while the keypad is in programming mode. Otherwise, it may cause error to the data
in memory.
c) DIRECT ACCESS TO PROGRAMMING MODE WITH “DAP” CODE -- 2 8 2 8
In case the Master Code is forgotten, apply the following procedures precisely to set keypad into programming
mode with DAP jumper & DAP code:
1. Switch OFF all the power for 1 minute to ensure that the keypad is fully discharged. Then, open the keypad box
carefully.
2. Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer gives continuous beeps and
the Status LED is ashing. This is the only time frame for accepting direct access to programming mode.
3. - Use a metal wire to momentary touch the “EG IN” terminal and the “(–) GND” erminal on the keypad.
- The power-up beeping stops
- Now the keypad is ready to accept the DAP code 2828.