Instructions

22
4. Key in the DAP code 2828 and validate it with * *. The Status LED is ON and the keypad is in
programming mode like using Master Code. It is ready to accept new programming data as long as you like until
exit programming mode.
DAP CODE
VALIDATION
2828 **
5. To program a new Master Code to replace the old one. See “Record A Master Code” stated at “Location 01
for the details.
The keypad will set itself to normal operation mode 1 minute after power-up if the DAP jumper and DAP
code are not operated properly. To set keypad back to power-up mode, repeat procedures 1-4.
Direct access to programming does not affect the stored data in the programming locations.
d) SYSTEM REFRESHING WITH “REFRESHING CODE” --- 9 9 9 9
The keypad can be refreshed by cleaning all the programmed old data and set it back to default values except the
Master Code.
REFRESHING CODE
VALIDATION
9999 #
Make sure that system refreshing is really required before entering the refreshing code.
Refreshing takes few minutes. The status LED (amber) keeps ashing during refreshing.
The keypad is back to its default value after refreshing. Re-program of the desired values are necessary.
e) THE DEFAULT VALUES AFTER REFRESHING
LOCATION PARAMETERS DEFAULT FUNCTIONS & VALUES
0 1 Master Code 0 0 0 0 Factory Set, Not a default value *
0 2 Super User Codes Nil ----- User Program Required
0 3 Common User Code 1 Nil ----- User Program Required
0 4 Common User Code 2 Nil ----- User Program Required
0 5 Common User Code 3 Nil ----- User Program Required
1 0 User Codes & Cards for O/P 1 Nil ----- User Program Required
2 0 User Codes & Cards for O/P 2 Nil ----- User Program Required
3 0 User Codes & Cards for O/P 3 Nil ----- User Program Required
4 0 Visitor Codes Nil ----- User Program Required
4 1 Duress Code for O/P 1 Nil ----- User Program Required
4 2 Duress Code for O/P 2 Nil ----- User Program Required
4 3 Duress Code for O/P 3 Nil ----- User Program Required
5 1 O/P Mode of The O/P 1 Time = 5 Sec, Momentary
5 2 O/P Mode of The O/P 2 Time = 5 Sec, Momentary
5 3 O/P Mode of The O/P 3 Time = 5 Sec, Momentary
5 5 System Real-Time-Clock Nil ----- User Program Required