Instructions
24
14. SUPER USER CODE -- Location 02
The Super User Code has TWO functions. It is prepared to operate the three outputs and make operation of inhibit
enable / disable to those outputs.
LOCATION
→
SUPER USER CODE
→
VALIDATION
02
4 to 8 DIGITS
#
(1) (2) (3)
(1) LOCATION
• Key in Location 02
(2) SUPER USER CODE
• The Super User Code can be 4 to 8 digits.
• When a new Super User Code is keyed in and conrmed, the old one is replaced.
(3) VALIDATION
• Pressing # key to conrm code entry.
Example:
• Set a Super User Code “2 5 8 0” ---- 02 2580 #
• Deleted a Super User Code from memory: Key in the Location number and #. ---- 02 #
OPERATION AND FUNCTIONS OF THE SUPER USER CODE
1) Operate Output 1, 2, and 3
The operation of the Super User Code is just like a normal User Code. Simply key-in the Code with a specic output
number for the desired Output. The Super User Code can also be used to reset an operating output timer instantly.
SUPER USER CODE
# 1
---------- Output 1 Activates or Resets
SUPER USER CODE
# 2
---------- Output 2 Activates or Resets
SUPER USER CODE
# 3
---------- Output 3 Activates or Resets
Optional Functions Controlled by Super User Code for Output 1
Apart from controlling of the three outputs 1, 2, and 3; the Super User Code can also be used to enable the optional
functions controlling Output 1 for user convenience or security enhancement.
Super User Code and Egress Button are excluded from any system inhibition and lockup functions; they are valid
for door open at anytime for safety.
2) Override The Door Lock Controlled by Output 1 (Keep Door Un-locked)
The Output 1 is usually for door lock control. In some situations, the door may require un-locked for a period of time
to allow door opening without User Code or EM Card for entry / exit convenience. This function Starts / Stops in
toggle with the following code entry.
SUPER USER CODE
# 7
---------- The Door is Un-locked, Start / Stop in Toggle