Instructions

25
The door is un-locked while the function is enabled.
Do not forget to stop this function after use because the door is un-locked. Also, the system refuses the
optional functions (3) & (4) while Override function comes into effect.
This feature is good for all the “Fail-safe electric locks”.
Fail-secure electric lock” requires power to keep in un-locked condition. It takes high current all the time
while the function comes into effect and may cause damage to it. This function is not recommended for
Fail-secure electric lock.
While
SUPER USER CODE
# 7 is in operation to hold the door lock open, the functions that rely
on the door sensor (such as a magnetic contact) and the User Codes for output 1 are all temporarily
suspended until
SUPER USER CODE
# 7 is keyed in again to release the door hold function.
The following are the temporarily suspended functions:
Door Auto-relock
Door Forced Open Warning (at Location 80)
Door Propped-up Warning (at Location 81)
Door Opening Alarm (at Location 91)
Dual Keypad Inter-lock Operation
All User Codes Including Super User Code for Output 1
Duress Output Actuated by The Duress Code for Output 1
3) Pause The Scheduled Daily Inhibition for Output 1 (Temporarily Disable The Inhibition)
The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop times. It can be
stopped temporarily if required; such as the staff work overtime after ofce hours going into the inhibition period.
This function Starts / Stops in toggle with the following code entry. It can be done before or during the inhibition
period.
SUPER USER CODE
# 8
------ Door Lock Operation Resumes, Start / Stop in Toggle
The “INHIBIT” LED (Red) is ON in inhibition and turns to Flashing while pause is into effect.
See Programming Locations 55 & 56 for more information Daily Inhibition.
4) Inhibit All The User Codes & EM Cards for Output 1 (Disable Access Control Manually)
To enhance the security of the access control keypad, the owner can stop the keypad after ofce hour or while
the house is nobody inside. Once the Output 1 (for door lock control) is inhibited, all the User Codes / Cards for it
become invalid and those people holding the User Code or Card are refused. This function Starts / Stops in toggle
with the following code entry.
SUPER USER CODE
# 9
------ Door Lock Operation Inhibited, Start / Stop in Toggle
The door is locked during Output 1 inhibited and the “INHIBIT” LED (Red) is ON.
Inhibition applies to all User Codes and EM Cards for Output 1 only. Output 2 and output 3 are not affected.