Instructions
25
The door is un-locked while the function is enabled.
Do not forget to stop this function after use because the door is un-locked. Also, the system refuses the
optional functions (3) & (4) while Override function comes into effect.
This feature is good for all the “Fail-safe electric locks”.
“Fail-secure electric lock” requires power to keep in un-locked condition. It takes high current all the time
while the function comes into effect and may cause damage to it. This function is not recommended for
Fail-secure electric lock.
While
SUPER USER CODE
# 7 is in operation to hold the door lock open, the functions that rely
on the door sensor (such as a magnetic contact) and the User Codes for output 1 are all temporarily
suspended until
SUPER USER CODE
# 7 is keyed in again to release the door hold function.
The following are the temporarily suspended functions:
• Door Auto-relock
• Door Forced Open Warning (at Location 80)
• Door Propped-up Warning (at Location 81)
• Door Opening Alarm (at Location 91)
• Dual Keypad Inter-lock Operation
• All User Codes Including Super User Code for Output 1
• Duress Output Actuated by The Duress Code for Output 1
3) Pause The Scheduled Daily Inhibition for Output 1 (Temporarily Disable The Inhibition)
The scheduled inhibition can be programmed and applied to Output 1 with daily start and stop times. It can be
stopped temporarily if required; such as the staff work overtime after ofce hours going into the inhibition period.
This function Starts / Stops in toggle with the following code entry. It can be done before or during the inhibition
period.
SUPER USER CODE
# 8
------ Door Lock Operation Resumes, Start / Stop in Toggle
The “INHIBIT” LED (Red) is ON in inhibition and turns to Flashing while pause is into effect.
See Programming Locations 55 & 56 for more information Daily Inhibition.
4) Inhibit All The User Codes & EM Cards for Output 1 (Disable Access Control Manually)
To enhance the security of the access control keypad, the owner can stop the keypad after ofce hour or while
the house is nobody inside. Once the Output 1 (for door lock control) is inhibited, all the User Codes / Cards for it
become invalid and those people holding the User Code or Card are refused. This function Starts / Stops in toggle
with the following code entry.
SUPER USER CODE
# 9
------ Door Lock Operation Inhibited, Start / Stop in Toggle
The door is locked during Output 1 inhibited and the “INHIBIT” LED (Red) is ON.
Inhibition applies to all User Codes and EM Cards for Output 1 only. Output 2 and output 3 are not affected.