Instructions

31
17. VISITOR CODES (FOR OUTPUT 1 ONLY) -- Location 40
The Visitor Codes are temporary user codes for Output 1 (mainly for door strike in access control). They can be
programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes will be cleared automatically after
use if they are one time codes, or, when the allowed time expires.
LOCATION
VISITOR ID
VALID PERIOD
VISITOR CODE
VALIDATION
40 01 - 50 00 or 01 - 99
4-8 DIGITS
#
(1) (2) (3) (4) (5)
(1) LOCATION
Key in Location 40
(2) VISITOR ID
01 - 50 --- 50 Visitor IDs for the 50 visitor codes. The ID is a Two-digit number
0999 --- Clear all the Visitor Codes in Location 40. Please see the Programming example below for the
details.
(3) VALID PERIOD
The codes in this box MUST be two digits and they represent the time of operation.
00 --- One Time Code
One Time Code has no time limit but it can only be used for ONCE. It is cleared by the systemautomatically
after use.
01 - 99 --- Time Limit in Hour(s)
The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a two-digit number of
01 to 99. The visitor code is cleared by the system when the time limit reaches.
(4) VISITOR CODES
The Visitor Codes can be 4-8 digits for Manual Mode code entry.
The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
The Visitor Codes can not reset Duress Output.
When a new Visitor Code is put in the same Code box, the old code is replaced.
All Visitor Codes will be cleared after power down to prevent extension/confusion of their valid time
limit.
(5) VALIDATION:
Press # key once. Two-beep conrms the entry.