Instructions

33
18. DURESS CODES (FOR OUTPUTS 1, 2 & 3) --
Locations 41, 42 & 43
Duress Codes are prepared for those Important Persons in case of DURESS while he is operating the access control
keypad. The duress code operates like a normal User Code for Output 1, 2 or 3, and at the same time activates the
Duress Output without any indication. The user may use it to report an emergency and ask for help silently when he is
forced to operate the keypad if the Duress Output is connected with a security system (for example, an Auto-dialer).
The Duress Codes are always valid. They are not governed by any inhibit or lockup function in the system.
LOCATIONS
CODE ID
DURESS CODE
VALIDATION
41 - 43 01 - 50
4-8 DIGITS
#
(1) (2) (3) (4)
(1) LOCATIONS
41 – Duress Codes for Output 1
42 – Duress Codes for Output 2
43 – Duress Codes for Output 3
(2) DURESS CODE IDs
01 - 50 50 Duress Codes IDs for The Output 1
01 - 10 10 Duress Codes IDs for The Output 2
01 - 10 10 Duress Codes IDs for The Output 3
0999 --- Clear all the Duress Codes from the selected Location group.
Please see the programming example below for the details.
(3) THE DURESS CODES
50, 10 and 10 Duress Codes can be programmed for Output 1, 2 and 3 respectively. They are stored in their two-digit
Code ID box. When a new Code is put into the same Code ID box, the old code is replaced.
The Duress Codes are 4-8 digits for Manual Mode code entry.
The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.
Always set a Duress Code that is easy to remember in Panic Situation. Only one number different from the daily
used User Code is highly recommended.
Example: User Code is 1 3 6 9, then 3 3 6 9 or 1 3 6 0 might be a good choice for the Duress Code.
The Duress Code can also be used to replace the Secondary User Code or Common User Code in Card
reading for the Duress reporting.
(4) VALIDATION:
Press # key once. Two-beep conrms the entry.