EXAMPLES:
Example 1: Set a “Duress Code” with the number of “3 3 6 9” for Output 1
41 01 3369 #
(a) (b) (c) (d)
(a) Duress Code for Output 1, (b) Duress Code ID, (c) The Duress Code, (e) Entry Conrmation
Example 2: Set a “Duress Code” with the number of “2 3 9 8 0” for Output 2
42 01 23980 #
(a) (b) (c) (d)
(a) Duress Code for Output 2, (b) Duress Code ID, (c) The Duress Code, (e) Entry Conrmation
Example 3: Delete an Output 1 “Duress Code” from Duress Code ID 01 in the memory
41 01 #
(a) (b) (c)
(a) Duress Code for Output 1, (b) The Duress Code ID, (c) Delete Conrmation
Example 4: Clear The Whole Group of Duress Codes from Location 41:
41 0999 #
(a) (b) (c)
(a) Group Location 41, (b) The Group Deletion Command, (c) Conrmation, all Duress Codes in Location 41
are cleared.
OPERATION AND FUNCTION OF THE DURESS CODE
The Duress Code(s) has double actions when it is keyed in. It activates the Duress Output (for duress alarm) and at
the same time activates the specic Relay Output 1, 2 or 3 just like a normal User Code. The Duress Code always
activates the Relay Output in its group, but, does not de-activate (stop) the Duress Output. ONLY a normal User
Code or Card in anyone of the user groups, or a Super User Code can reset (de-activate) the Duress Output.
For Example:
Key in The Duress Code 3 3 6 9 of the Group 1 (for Output 1) To Command The Duress Function:
3369# ----- Duress Output activates (switches to (-) ground) & Output 1 activates.
Key in The Duress Code 3 3 6 9 in Group 1 (for Output 1) Again:
3369# ----- Duress Output keeps activating and no change in its state (keeps to (-) ground) & Output 1 activates
again.
Key in A Normal User Code to Reset Duress (For Example: 1369 is An User Code for Output 1):
1369# ----- Duress Output resets (back to OFF state) but does not activate Output 1.
Report Duress in EM Card Operation
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User Code” or “EM Card
+ Common User Code” operation, they can be used to replace the “Secondary User Code” or the “Common User
Code” to operate the specic output and report a duress alarm event. Programming is not required. The system has
the function automatically while Duress Code exists.