Instructions
42
1 --- Standby Flashing ON -- (Default)
The Status LED gives Standby Flashing all the time. It also gives the light indications showing the operation
status of the system.
0 --- Standby Flashing OFF
The Standby Flashing is OFF but it does not affect the system status indications.
(3) VALIDATION
Press # key once. Two-beep conrms the entry.
27. DOOR FORCED OPEN WARNING & TIMING --
Location 80
LOCATION
→
FUNCTION MODES
→
VALIDATION
80 0 or 1 - 999 #
(1) (2) (3)
(1) LOCATION
Key in Location 80
(2) FUNCTION MODES FOR DOOR FORCED OPEN WARNING
The Door Forced Open Warning function works with a Door Position Sensing switch equipped on the door (usually a
magnetic contact). Once a Timing Figure is put into the Function Mode box, the warning mode is enabled.
0 --- Door Forced Open Warning OFF – (Default)
1 - 999 --- Door Forced Open Warning & Alarm Enabled & Timing
The Timing Figure for the Warning can be 1-999 seconds. The keypad generates the door forced open warning beeps
and activates the alarm output (Terminal 23) instantly if the door is forced to open without a valid User Code/Card or
pressing Egress Button. The beeps and alarm will last as long as the time set on the timer and it can be stopped at
anytime with an User Code/Card in Group 1 before the end of the time.
The Manner of The Door Forced Open Warning:
• The door is forced to open (without using Code/Card or Egress Button) – Warning & Alarm
• The door is opened with Code/Card – No Warning or Alarm
• The door is opened with Egress Button – No Warning or Alarm
(3) VALIDATION
Press # key once. Two-beep conrms the entry