30. DOOR OPENING ALARM & TIMER -- Location 91
LOCATION
→
ALARM TIME
→
VALIDATION
91 0 or 1 - 999 #
(1) (2) (3)
(1) LOCATION
Key in Location 91
(2) ALARM & TIMING OF DOOR OPENING
0 --- No Alarm – (Default)
The Alarm Output is disabled
1 - 999 --- Alarm Timer
The Door Open Alarm operates the Alarm Output (Terminal 23) only. It is mainly prepared to trigger
an optional alarm system. Put a Timing Figure of 1 to 999 into the box to enable the function of Door
Opening Alarm. The gure is the time in second of the alarm duration, which starts to count after the
door is opened and it resets automatically when the time reaches.
The alarm can be stopped with the User Codes/Cards or the Super User Code for Output 1 at any
time before the end of the alarm time.
The Door Opening Alarm is designed to protect the emergency exit door from use by the un-authorized
person. The alarm occurs when the door is opened or forced to open. However, Alarm will not happen if the
door is opened with a valid User Code or Card.
This function works with a door position sensing switch equipped on the door.
The Manner of The Door Opening Alarm:
• The door is forced to open without using Code/Card – Alarm
• The door is opened with Egress Button – Alarm
• The door is opened with Code/Card – No Alarm
To prevent confusion of the alarm outputs. It is suggested to disable the “Door Forced Open Warning” at Location 80
while “Door Opening Alarm” function is enabled. If both functions at Location 80 and Location 91 are enabled and are
set with different timings, the system will combine them and will take the longer one for alarm time.
(3) VALIDATION
Press # key once. Two-beep conrms the entry