32. WIEGAND DATA OUTPUT FORMAT -- Location 93
This features is only available to the keypads with Wiegand Data Output.
LOCATION
WIEGAND FORMAT
VALIDATION
93 1, 2 or 3 #
(1) (2) (3)
(1) LOCATION
Key in Location 93
(2) WIEGAND FORMAT FOR EM CARD & USER CODE
The Wiegand data output is programmable for 26-bit, 34-bit or 37-bit standard format.
1 26-Bit Wiegand Data Output
Bit 1: Even Parity Bit (bit 2 – bit 13)
Bit 2 – Bit 25: 24 Bit ID Number
Bit 26: Odd Parity Bit (bit 14 – bit 25)
2 34-Bit Wiegand Data Output
Bit 1: Even Parity Bit (bit 2 – bit 17)
Bit 2 – Bit 33: 32 Bit ID Number
Bit 34: Odd Parity Bit (bit 18– bit 33)
3 37-Bit Wiegand Data Output
Bit 1: Even Parity Bit (bit 2 – bit 19)
Bit 2 – Bit 36: 35 Bit ID Number
Bit 37: Odd Parity Bit (bit 19– bit 36)
(3) VALIDATION
Press # key once. Two-beep conrms the entry