Instructions
51
35. PROGRAMMING MAKE SIMPLE – FOR GENERAL
USERS
Split-decoded keypad is multi purpose keypad. It has many functions for user’s selection. For those general users
taking the keypad for door strike only, most of the features can be kept in their Default values. Only the User Codes /
Cards and a private Master Code are required to program.
The keypad accepts 1) Card only, 2) Code only, 3) Card + Code or 4) Card + Common User Code to operate its
outputs.
PROGRAMMING
The button is equivalent to the * button in some of the keypads.
Wait 1 minute until the end of power up delay, or keyin 12# to stop the power-up delay instantly and set
the keypad to normal operation mode.
1) Set System in Programming Mode with The Factory Set Master Code 0 0 0 0
0000 ** ---- 2 beeps, system is in Programming Mode
If the Master Code is forgotten, use the DAP Code to set the system into programming mode. See DAP
CODE 2828 for the details.
2) Change The Factory Set Master Code to Owner’s Private Master Code for Security Reason
01 3289 # ---- 2 beeps, 3 2 8 9 is a Master Code for example here only.
It replaces the old master code 0000.
3) Record an “EM Card” to Operate The Output 1 for Door Open
10 1 001
READ CARD
#
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 1 = Programming option for EM Card only
(c) 001 = One of the 1,000 User IDs for the User Code/Card from 000-999
(d) Read Card = Put the Card close to the card reader
(e) # = Conrm the card is read, 2 beeps
4) Set an “User Code” to Operate The Output 1 for Door Open
10 2 002 8321 #
(a) (b) (c) (d) (e)
(a) 10 = Programming Location for Output 1
(b) 2 = Programming option for User Code only
(c) 002 = One of the 1,000 User IDs for the User Code/Card from 000-999
(d) 8321 = The User Code for door open. It is for example here only
(e) # = Conrm the User Code, 2 beeps