(E) DURESS OUTPUT
LOW POWER
PIEZO BUZZER
LED
ALARM CONTROL PANEL
OR
24 HOUR N.O.
PROTECTION
ZONE
The Duress Output switches to (-) ground when duress code is entered. You may use it to turn ON an LED lamp and/
or a small buzzer to notify a guard; or connect it to a 24 hour Normally Open protection zone of an alarm system.
Only one connection option is recommended. Make sure that the sink current does not exceed the maximum rating
of 100mA.
40. THE OPTIONAL AUXILIARY READERS & KEYPADS
The split-decoded keypad is expandable to be a Multi-station System with its Data I/O Bus for the connection of the
optional auxiliary keypad(s). The wiring is very simple. Just connect all the devices in parallel with the Data I/O Bus.
The server keypad manages the data among of them.
A Multi-station System provides higher security and user convenience to operate an electric lock at different locations.
Such as a dual keypad system for area needs controlling of going in and going out with user codes or EM cards.
The application example 2 shows the connection of auxiliary keypad to the server keypad.
The version “A” auxiliary reader keypads are available, which also provide Wiegand and RS-232 data outputs.
Please contact your local agent for these optional devices.
AR-2802 AR-2806 AR-2807
Aux. Reader Aux. Reader-Keypad Aux. Reader-Keypad